Mostrar el registro sencillo del ítem

dc.contributor.advisorVásquez Alfaro, Iván Eugenio
dc.contributor.authorMendoza Jicaro, Jimena Virginia
dc.date.accessioned2018-09-25T23:41:36Z
dc.date.available2018-09-25T23:41:36Z
dc.date.issued2018-09-20
dc.identifier.citationMendoza, J. V. (2018). Influencia del porcentaje, tipo y dosificación de microsílice en la resistencia a la compresión y capilaridad en morteros elaborados con cemento tipo V, Trujillo 2017 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/13859es_PE
dc.identifier.other624.1833 MEND 2018es_PE
dc.identifier.urihttps://hdl.handle.net/11537/13859
dc.description.abstractLa presente investigación tiene como finalidad evaluar la influencia de la adición de microsílice industrial como Sika Fume y Silica Fume QS, sobre la resistencia a la compresión y capilaridad, en morteros elaborados con cemento tipo V, con relación cemento : arena de 1:3 y 1:4, con porcentajes adición respecto al cemento de 0% al 10%, con una relación agua/cemento de 0.65 y 0.70; adicionando a la vez el aditivo acelerante Accelguard 80 de QSI con 1.5% de adición, utilizando arena gruesa de la cantera “Lekersa” de Huanchaco. Desarrollándolo bajo las normas: Sociedad Americana para Pruebas y Materiales (ASTM) e Instituto Americano del Concreto (ACI), granulometría (ASTM C136 y NTP 400.012), humedad (ASTM 566 y NTP 339.185), peso específico y absorción (ASTM C128 y NTP 400.022), peso unitario seco suelto y compactado (ASTM C29 y NTP 400.017), compresión (ASTM C109) y capilaridad (ASTM C1585). Se elaboraron probetas de 5cm x 5cm x 5 cm, donde fueron curados en solución de hidróxido de calcio a 7, 28 y 56 días, con un total de 756 probetas cubicas, obteniendo como resultado, que la que mejor resistencia a 28 días en mortero convencional, fue la dosificación c:a de 1:3, con 259 kg/cm , las probetas a 28 días, agregadas con microsílice Sika Fume tuvieron una mejor resistencia siendo el de 8% el porcentaje más óptimo con 401 kg f/cm 2 2 con relación 1:3, aumentando 54.2% de resistencia en base a la resistencia patrón, concluyendo que el mortero adicionado con microsílice sika fume tiene altas resistencias iniciales con una baja absorvencia que disminuye el fleco capilar en el mortero. Por otro lado, el mortero adicionado con microsílice silica fume QS, tiene buenos resultados a 28 días con 8% de adición con 385 kgf/cm 2 de resistencia siendo un mortero de buena calidad, pero de crecimiento inestable, su capilaridad llega a ser de absorvencia media, esto es debido al tamaño de partículas de la microsílice, haciendo que se absorba más agua. La capilaridad de menor absorvencia está en el 8% de adición y en dosificaciones ente el 6% y 9% de adición, del grupo de morteros adicionados con microsílice Sika Fume y aditivo acelerador Accelguard 80, obteniendo mezclas de mortero de baja absorvencia.es_PE
dc.description.abstractThe purpose of this research is to evaluate the influence of the addition of industrial microsilica such as Sika Fume and Silica Fume QS, on the resistance to compression and capillarity, in mortars made with type V cement, with cement: sand ratio of 1: 3 and 1: 4, with percentages in addition to cement from 0% to 10%, with a water / cement ratio of 0.65 and 0.70; adding at the same time the accelerator additive Accelguard 80 of QSI with 1.5% addition, using coarse sand from the quarry "Lekersa" of Huanchaco. Developed under the standards: American Society for Testing and Materials (ASTM) and American Concrete Institute (ACI), granulometry (ASTM C136 and NTP 400.012), humidity (ASTM 566 and NTP 339.185), specific gravity and absorption (ASTM C128 and NTP 400.022), loose and compacted dry unit weight (ASTM C29 and NTP 400.017), compression (ASTM C109) and capillarity (ASTM C1585). Test pieces of 5cm x 5cm x 5cm were prepared, where they were cured in calcium hydroxide solution at 7, 28 and 56 days, with a total of 756 cube specimens, obtaining as a result, the best resistance to 28 days in mortar. conventional, was the dosage c: a of 1: 3, with 259 kg / cm , the specimens at 28 days, added with Sika Fume microsilica had a better resistance being 8% the most optimal percentage with 401 kg f / cm with a 1: 3 ratio, increasing 54.2% resistance based on the resistance pattern, concluding that the mortar added with sika microsilica fume improves has high initial resistance with a low absorbency that decreases the capillary fringe in the mortar. On the other hand, the mortar added with silica fume silica QS, has good results at 28 days with 8% addition with 385 kgf / cm 2 2 of resistance being a mortar of good quality, but of unstable growth, its capillarity becomes absorbency medium, this is due to the particle size of the microsilica, causing more water to be absorbed. The capillarity of lower absorbency is in 8% addition and in dosages between 6% and 9% addition, from the group of mortars added with Sika Smoke microscope and Accelguard 80 accelerator additive, obtaining mortar mixtures of low absorbency.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de Américaes_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectCementoes_PE
dc.subjectResistencia a la comprensiónes_PE
dc.subjectIngeniería civiles_PE
dc.titleInfluencia del porcentaje, tipo y dosificación de microsílice en la resistencia a la compresión y capilaridad en morteros elaborados con cemento tipo V, Trujillo 2017es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeTrujillo San Isidroes_PE
renati.advisor.dni80524374
renati.advisor.orcidhttps://orcid.org/0000-0002-6717-0501es_PE
renati.author.dni74383216
renati.discipline732016es_PE
renati.jurorVillar Quiroz, Josualdo
renati.jurorVásquez Díaz, Alberto
renati.jurorFernández Fernández, Carlos
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess