Influencia del tamaño de vidrio molido en la resistencia a compresión del concreto, Trujillo 2019
dc.contributor.advisor | Vásquez Díaz, Alberto Rubén | |
dc.contributor.author | Chávez Silva, Ana Felicitas | |
dc.date.accessioned | 2019-05-10T14:16:32Z | |
dc.date.available | 2019-05-10T14:16:32Z | |
dc.date.issued | 2019-04-17 | |
dc.identifier.citation | Chávez, A. F. (2019). Influencia del tamaño de vidrio molido en la resistencia a compresión del concreto, Trujillo 2019 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/21164 | es_PE |
dc.identifier.other | 624.1838 CHAV 2019 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/21164 | |
dc.description.abstract | La investigación, tiene como objetivo determinar la influencia del tamaño de vidrio molido sobre la resistencia a compresión del concreto, reduciendo la contaminación utilizando residuos de vidrio. Se plantea el uso del vidrio residual como una alternativa para la elaboración del concreto, reemplazando el 30%, 40%, 50% y 60% para cada tamaño de agregado fino por los mismos porcentajes y tamaño de vidrio molido, con una relación de agua/cemento de 0.56. Se utilizó agregado fino con un módulo de finura de 2.71, cemento Pacasmayo Tipo I. Se realizaron los ensayos de caracterización para los agregados tales como granulometría, contenido de humedad, peso unitario suelto y compactado, peso específico y absorción. Los especímenes para el ensayo a compresión fueron cilíndricos de 4” de diámetro y 8” de altura. El diseño más óptimo se dio con el 60% de vidrio de la malla #8 sustituyendo por ese porcentaje y tamaño de agregado fino, con valores de una resistencia promedio a los 7 días de 205 kg/cm2 y a los 28 días con una resistencia promedio de 249 kg/cm2. Mientras más porcentaje de vidrio del tamaño de la abertura de la malla #8 reemplazando al agregado fino dio mejores resultados de resistencia a compresión. | es_PE |
dc.description.abstract | The objective of the investigation is to determine the influence of the size of the ground glass on the compressive strength of the concrete, reducing the contamination using glass waste. The use of waste glass as an alternative to the manufacture of concrete is proposed, replacing 30%, 40%, 50% and 60% for each size of fine aggregate by the same percentages and size of ground glass, with a water / cement ratio of 0.56. Fine aggregate was used with a fineness modulus of 2.71, Pacasmayo Type I cement. Characterization tests were performed for aggregates such as granulometry, moisture content, loose and compacted unit weight, specific weight and absorption. The specimens for the compression test were cylindrical 4" in diameter and 8" in height. The most optimal design was given with 60% glass of the # 8 mesh substituting for that percentage and size of aggregate, with values of an average resistance to the 7 days of 204.39 kg/cm2 and to the 28 days with an average resistance of 249.24 kg/cm2. The more percentage of glass in the # 8 mesh replacing the fine aggregate gave better compression resistance. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.format | application/msword | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/2.5/pe/ | * |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Concreto/Hormigón | es_PE |
dc.subject | Resistencia de materiales | es_PE |
dc.subject | Vidrio | es_PE |
dc.subject | Resistencia a la compresión | |
dc.subject | Construcción | |
dc.title | Influencia del tamaño de vidrio molido en la resistencia a compresión del concreto, Trujillo 2019 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Trujillo San Isidro | es_PE |
renati.advisor.dni | 40385695 | |
renati.advisor.orcid | https://orcid.org/0000-0001-9018-5763 | |
renati.author.dni | 75063631 | |
renati.discipline | 732016 | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis [1439]