Mostrar el registro sencillo del ítem

dc.contributor.advisorVásquez Díaz, Alberto Rubén
dc.contributor.authorCarranza Castillo, Antony Augusto
dc.date.accessioned2021-05-18T15:11:19Z
dc.date.available2021-05-18T15:11:19Z
dc.date.issued2021-03-31
dc.identifier.citationCarranza, A. A. (2020). Influencia del polipropileno reciclado como reemplazo del agregado grueso sobre el esfuerzo a la compresión y absorción capilar de un concreto convencional, Trujillo 2020 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/26568es_PE
dc.identifier.other624.1834 CARR 2020es_PE
dc.identifier.urihttps://hdl.handle.net/11537/26568
dc.description.abstractAligerar el peso del concreto mediante la transformación físico-química de un material muy contaminante como plástico y generando un segundo uso de este, minimizando los impactos ambientales que genera tanto el desperdicio del plástico como la depredación de los recursos naturales como la pierda, es por ello que en esta investigación se reemplazó el agregado grueso de un concreto convencional por agregados plásticos al 25%, 50% 75% y 100% y se realizaron los diseños de acuerdo con lo establecido en la norma ACI 211. Se realizaron ensayos de caracterización a los agregados naturales y el agregado de polipropileno reciclado; al concreto en estado fresco se le evaluó el asentamiento, temperatura y peso unitario, para los ensayos en estado endurecido se elaboraron un total de 45 probetas cilíndricas de 4” x 8”, evaluando la resistencia a compresión promedio a 7 y 28 días de curado. También se elaboraron 15 probetas de 4” x 8” para determinar la succión capilar promedio a 28 días de curado. En base a los resultados obtenidos se determinó que la mejor opción para la fabricación de concreto estructural es con un 25% de agregado de concreto plástico ya que a los 28 días de curado alcanzó una resistencia promedio de 214 kgf/cm2, una velocidad de succión capilar promedio de 16.108 g/ (m2*s1/2) y su costo de producción es de S/. 233.21 Nuevos soles.es_PE
dc.description.abstractLighten the weight of concrete through the physical-chemical transformation of a highly polluting material such as plastic and generating a second use of it, minimizing the environmental impacts generated by both the waste of plastic and the depredation of natural resources as lost, is for Therefore, in this investigation, the coarse aggregate of a conventional concrete was replaced by plastic aggregates at 25%, 50%, 75% and 100% and the designs were made in accordance with the provisions of the ACI 211 standard. Characterization tests were carried out on natural aggregates and plastic aggregates; Concrete in a fresh state was evaluated for settlement, temperature and unit weight, for the hardened state tests, a total of 45 4 "x 8" cylindrical specimens were made, evaluating the average compressive strength at 7 and 28 days after curing. . Also, 15 4 "x 8" test tubes were made to determine the average capillary suction at 28 days of curing. Based on the results obtained, it was determined that the best option for the manufacture of structural concrete is with 25% plastic concrete aggregate, since at 28 days of curing it reached an average resistance of 214 kgf /cm2, a suction speed average capillary of 16.108 g/ (m2 * s1 / 2) and its production cost is S /. 233.21 Nuevos soles.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/embargoedAccesses_PE
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectConcretoes_PE
dc.subjectResistencia a la compresiónes_PE
dc.subjectResistencia de materialeses_PE
dc.titleInfluencia del polipropileno reciclado como reemplazo del agregado grueso sobre el esfuerzo a la compresión y absorción capilar de un concreto convencional, Trujillo 2020es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeTrujillo San Isidroes_PE
renati.advisor.dni40385695
renati.advisor.orcidhttps://orcid.org/0000-0001-9018-5763es_PE
renati.author.dni47524465
renati.discipline732016es_PE
renati.jurorAzañedo Medina, Wiston Henry
renati.jurorAcosta Sánchez, Luis Alberto
renati.jurorRodriguez Beltrán, Eduar José
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem