Comparación del comportamiento sísmico y el costo de ejecución del bloque N° 05 del Hospital Regional de Pasco considerando y obviando el uso de aisladores elastoméricos
Date
2016-09-13Author(s)
Salazar Tasilla, Misael
Urteaga Loayza, Waldir Manuel
Metadata
Show full item recordAbstract
RESUMEN
El presente estudio está orientado al análisis comparativo del comportamiento sísmico y el costo de ejecución de un edificio hospitalario, considerando y obviando para su cimentación el uso de aisladores símicos de base, para ello se ha elegido el bloque N° 05 del Hospital Regional de Pasco, como modelo de estudio. Los edificios hospitalarios son considerados esenciales según la normativa E.030 del reglamento nacional de edificaciones, es por ello que después de un evento sísmico no pueden sufrir daños, ya que su función principal es brindar auxilio inmediato a las posibles víctimas del evento sísmico. Se realizó en primer lugar un modelamiento del edificio, el cual fue analizado con el uso del programa ETABS 15 versión educacional, se analizó la estructura con una cimentación convencional, luego se hicieron modificaciones complementarias al modelo, para poder lograr generar un nivel de aislación (interface de aislamiento) en donde estarán ubicados los aisladores, para ello fue necesario adicionar un diafragma, que cumplirá la función de piso del primer nivel de la estructura, el cual está conformada por una propia losa, vigas y elementos llamados capiteles estos últimos sirven de inicio para las columnas. El diseño de los aisladores se realizó bajo la norma ASCE 7-10, los factores obtenidos del diseño fueron ingresados al modelo de análisis procesado con el programa ETABS 15 versión educacional. Para obtener la respuesta sísmica del edificio, ambos modelos fueron sometidos al espectro símico generado según norma E.030 del reglamento nacional de edificaciones, posteriormente a los análisis se midió y comparó, los desplazamientos en el centro de masa, las derivas, las fuerzas cortante estática y dinámica. Se registraron las sigues variaciones en una estructura aislada: en desplazamientos disminuye a 45%, la máxima deriva disminuye en 50%, la fuerza cortante en la base disminuye a 31% y el costo de la estructura aumenta en 18%, en comparación a una estructura sin aislar.
Mostrar más
ABSTRACT
This study is oriented comparative analysis of seismic behavior and the cost of running a hospital
building, considering and ignoring for foundation using simian base isolators, for it has been
selected block No. 05 of the Regional Hospital of Pasco, as a study model. The hospital buildings
are considered essential according to E.030 regulations National Building Regulations, which is
why after a seismic event cannot be damaged, since its main function is to provide immediate
potential victims of earthquake relief event. one modeling the building, which was analyzed using
the ETABS program 15 educational version was performed first, the structure was analyzed with a
conventional foundation, then additional modifications were made to the model, in order to achieve
generate a level of isolation ( isolation interface) where will be located the insulators, for it was
necessary to add a diaphragm, which will act as the floor of the first level of the structure, which is
made up of its own slab, beams and elements called capitals latter serve home for columns. The
design of the insulators was carried out under the ASCE 7-10 standard design factors obtained
were entered into the analysis model processed with 15 educational program ETABS version. For
the seismic response of the building, both models were subjected to the simian spectrum
generated according to standard E.030 of the National Building Regulations, then the analysis was
measured and compared, displacement in the center of mass drifts, the shear forces static and
dynamic. the follow variations were recorded in an isolated structure: displacement decreases to
45%, the maximum drift decreases by 50%, the shear force at the base decreases to 31% and the
cost of the structure increases by 18%, compared to a structure uninsulated.
Mostrar más
Bibliographic citation
Salazar, M., & Urteaga, W. M. (2016). Comparación del comportamiento sísmico y el costo de ejecución del bloque N° 05 del Hospital Regional de Pasco considerando y obviando el uso de aisladores elastoméricos (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/9939
Collections
- Tesis [1643]
Related items
Showing items related by title, author, creator and subject.
-
Comparación de la respuesta estructural de los módulos B y C de la I. E. Julio Ramón Ribeyro considerando y sin considerar la interacción suelo - estructura
Aquino Carmona, Cristhian Michael; Rodríguez Cortez, Mayra Thalía (Universidad Privada del Norte, 2015-06-01)Acceso abiertoRESUMEN En Cajamarca la interacción suelo – estructura no es tomada en cuenta en el análisis y diseño de edificaciones debido a que no está considerada en la normativa peruana, además de contar con poca información ... -
Evaluación del aislador elastomérico y triple péndulo según Norma E.031, para la mejora de la respuesta sísmica del hospital Mi Perú, región Callao
Durand Salazar, Naysha Antuannett (Universidad Privada del Norte, 2020-11-29)Acceso abiertoEl presente trabajo de investigación tuvo como objetivo determinar de qué manera mejorará la respuesta sísmica del Hospital Mi Perú con la evaluación del Aislador Elastomérico y Aislador Triple Péndulo según la Norma ... -
Diseño y evaluación del desempeño sísmico en el edificio "Residencial Samiria II" incorporando disipadores de energía de fluido viscoso en disposición diagonal sin modificar su diseño arquitectónico, Lima - 2020
Eguizabal Espinoza, Emer Rider (Universidad Privada del Norte, 2021-10-01)Acceso abiertoLa presente investigación estudiara los sistemas de protección sísmica con disipadores de energía, dando énfasis al sistema de fluido viscoso en disposición diagonal, que se centra en desarrollar y mostrar todo el proceso ...