Show simple item record

dc.contributor.advisorMosqueira Moreno, Miguel Ángel
dc.contributor.authorSalazar Tasilla, Misael
dc.contributor.authorUrteaga Loayza, Waldir Manuel
dc.date.accessioned2017-05-17T22:16:45Z
dc.date.available2017-05-17T22:16:45Z
dc.date.issued2016-09-13
dc.identifier.citationSalazar, M., & Urteaga, W. M. (2016). Comparación del comportamiento sísmico y el costo de ejecución del bloque N° 05 del Hospital Regional de Pasco considerando y obviando el uso de aisladores elastoméricos (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/9939es_PE
dc.identifier.other624 URTE 2016es_PE
dc.identifier.urihttps://hdl.handle.net/11537/9939
dc.description.abstractRESUMEN El presente estudio está orientado al análisis comparativo del comportamiento sísmico y el costo de ejecución de un edificio hospitalario, considerando y obviando para su cimentación el uso de aisladores símicos de base, para ello se ha elegido el bloque N° 05 del Hospital Regional de Pasco, como modelo de estudio. Los edificios hospitalarios son considerados esenciales según la normativa E.030 del reglamento nacional de edificaciones, es por ello que después de un evento sísmico no pueden sufrir daños, ya que su función principal es brindar auxilio inmediato a las posibles víctimas del evento sísmico. Se realizó en primer lugar un modelamiento del edificio, el cual fue analizado con el uso del programa ETABS 15 versión educacional, se analizó la estructura con una cimentación convencional, luego se hicieron modificaciones complementarias al modelo, para poder lograr generar un nivel de aislación (interface de aislamiento) en donde estarán ubicados los aisladores, para ello fue necesario adicionar un diafragma, que cumplirá la función de piso del primer nivel de la estructura, el cual está conformada por una propia losa, vigas y elementos llamados capiteles estos últimos sirven de inicio para las columnas. El diseño de los aisladores se realizó bajo la norma ASCE 7-10, los factores obtenidos del diseño fueron ingresados al modelo de análisis procesado con el programa ETABS 15 versión educacional. Para obtener la respuesta sísmica del edificio, ambos modelos fueron sometidos al espectro símico generado según norma E.030 del reglamento nacional de edificaciones, posteriormente a los análisis se midió y comparó, los desplazamientos en el centro de masa, las derivas, las fuerzas cortante estática y dinámica. Se registraron las sigues variaciones en una estructura aislada: en desplazamientos disminuye a 45%, la máxima deriva disminuye en 50%, la fuerza cortante en la base disminuye a 31% y el costo de la estructura aumenta en 18%, en comparación a una estructura sin aislar.es_PE
dc.description.abstractABSTRACT This study is oriented comparative analysis of seismic behavior and the cost of running a hospital building, considering and ignoring for foundation using simian base isolators, for it has been selected block No. 05 of the Regional Hospital of Pasco, as a study model. The hospital buildings are considered essential according to E.030 regulations National Building Regulations, which is why after a seismic event cannot be damaged, since its main function is to provide immediate potential victims of earthquake relief event. one modeling the building, which was analyzed using the ETABS program 15 educational version was performed first, the structure was analyzed with a conventional foundation, then additional modifications were made to the model, in order to achieve generate a level of isolation ( isolation interface) where will be located the insulators, for it was necessary to add a diaphragm, which will act as the floor of the first level of the structure, which is made up of its own slab, beams and elements called capitals latter serve home for columns. The design of the insulators was carried out under the ASCE 7-10 standard design factors obtained were entered into the analysis model processed with 15 educational program ETABS version. For the seismic response of the building, both models were subjected to the simian spectrum generated according to standard E.030 of the National Building Regulations, then the analysis was measured and compared, displacement in the center of mass drifts, the shear forces static and dynamic. the follow variations were recorded in an isolated structure: displacement decreases to 45%, the maximum drift decreases by 50%, the shear force at the base decreases to 31% and the cost of the structure increases by 18%, compared to a structure uninsulated.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/embargoedAccesses_PE
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectAnálisis sísmico de edificioses_PE
dc.subjectAislamientoes_PE
dc.subjectHospitaleses_PE
dc.titleComparación del comportamiento sísmico y el costo de ejecución del bloque N° 05 del Hospital Regional de Pasco considerando y obviando el uso de aisladores elastoméricoses_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeCajamarcaes_PE
renati.advisor.dni26733060
renati.advisor.orcidhttps://orcid.org/0000-0003-2668-4909es_PE
renati.author.dni46522630
renati.author.dni72882538
renati.discipline732016es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record