dc.identifier.citation | Malca, J. R., & Quiroz, R. A. (2016). Eficiencia de un sistema de suministro de agua por impulsión utilizando bombas de ariete hidráulico con válvulas en serie y en paralelo (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/10256 | es_PE |
dc.identifier.other | 624 MALC 2016 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/10256 | |
dc.description.abstract | RESUMEN
La presente tesis determinó experimentalmente, mediante ensayos de laboratorio la
eficiencia de un sistema de suministro de agua por impulsión utilizando una bomba de
ariete hidráulico con dos válvulas trabajando en serie, para un primer escenario, y con
dos válvulas trabajando en paralelo para un segundo escenario, obteniendo resultados
que nos permitieron realizar una evaluación comparativa entre estos dos sistemas
hidráulicos.
Para la realización de los ensayos se construyó dos bancos de pruebas, uno para el
sistema hidráulico trabajando con las válvulas en serie y otro para el sistema hidráulico
trabajando con las válvulas en paralelo, ambos correspondientes a una bomba de ariete
hidráulico de dos pulgadas de diámetro, con la mayoría de sus accesorios de fierro
galvanizado. Los bancos de pruebas fueron ensayados en el laboratorio de hidráulica de
la Universidad Privada del Norte - Cajamarca, lugar donde se tomaron todos los datos de
la investigación; sin embargo, posteriormente fueron llevados a campo, exactamente, al
viaducto que se encuentra en los Baños del Inca – Cajamarca – Cajamarca, en donde se
comprobó su funcionamiento óptimo para ambos sistemas hidráulicos.
En laboratorio se realizaron 09 ensayos para cada sistema hidráulico, en el cual se
mantuvo una altura de suministro constante y se definieron tres alturas de entregas, para
tres tipos de caudales de suministro, seguidamente se determinaron nueve caudales de
entrega mediante el método volumétrico y finalmente con este conjunto de parámetros se
determinó la eficiencia de cada sistema hidráulico. Para la confiabilidad de datos se
empleó el método de mitades partidas, obteniendo una confiabilidad elevada con un 90%
a 100%, para los datos de la eficiencia de los sistemas hidráulicos.
Al finalizar la toma de datos en laboratorio se procedió a la obtención y análisis de
resultados, concluyendo que el sistema de suministro de agua por impulsión utilizando
una bomba de ariete hidráulico con dos válvulas trabajando en serie, es más eficiente
que el sistema de hidráulico trabajando con dos válvulas en paralelo, en 112% con
respecto a sus máximas eficiencias obtenidas. | es_PE |
dc.description.abstract | ABSTRACT
This thesis determined experimentally, through laboratory testing, the efficiency of an
impulsion water supply system using a hydraulic ram pump with two valves working in
series, for a first scenario, and with two valves working in parallel for a second scenario.
Obtaining results that allowed us to make a comparative evaluation between these two
hydraulic systems.
For carrying out the tests, two banks of samples were built. The first one consisting of a
hydraulic system working with valves in series and the second one working with valves in
parallel, both corresponding to a hydraulic ram pump of two inches in diameter, with the
majority of its accessories composed of galvanized iron. The two Banks were tested in the
hydraulics laboratory of the Universidad Privada del Norte- Cajamarca, where all the
research data was collected; however, afterwards they were taken to the field, precisely,
to the viaduct located in the city of Baños del Inca - Cajamarca - Cajamarca, the optimum
performance of both hydraulic systems was corroborated.
In laboratory 09 tests for each hydraulic system were performed, in which a constant
supply height remained and three heights of deliveries were defined, for three types of
flow rates. Afterwards, nine flow delivery rates were determined by the volumetric method
and finally with this parameter the efficiency of each hydraulic system was determined.
For data reliability, the split halves method was used, resulting in a high range within 90%
to 100%, for the data efficiency of the hydraulic systems.
Upon completion of data collection in the laboratory we proceeded to the collection and
analysis of results, concluding that the system of water supply drive using a hydraulic ram
pump with two valves working in series, is more efficient than the hydraulic working with
two valves in parallel, by 112% from their peak efficiencies obtained. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.format | application/msword | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Suministro de agua | es_PE |
dc.subject | Agua potable | es_PE |
dc.subject | Hidrología | es_PE |
dc.title | Eficiencia de un sistema de suministro de agua por impulsión utilizando bombas de ariete hidráulico con válvulas en serie y en paralelo | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Trujillo El Molino | es_PE |
renati.advisor.dni | 26693344 | |
renati.advisor.orcid | https://orcid.org/0000-0001-8861-7889 | es_PE |
renati.author.dni | 46502024 | |
renati.author.dni | 45885468 | |
renati.discipline | 732016 | es_PE |
renati.juror | Aguilar Aliaga, Orlando | |
renati.juror | Ravines Azañero, Irene | |
renati.juror | Cubas Becerra, Alejandro | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |