dc.description.abstractRESUMEN El concreto es un material que se utiliza en la construcción de diferentes tipos de edificaciones, en muchos casos se recomienda el uso de aditivos, para mejorar algunas propiedades del concreto, entre una de ellas está la de disminuir la permeabilidad del mismo. Es por ello que en la presente tesis, se va a investigar la permeabilidad del concreto f’c = 210 kg/cm2 , para lo cual se utilizó aditivo Sika Cem Plastificante, en porcentajes de 2% y 4% que se adicionaron a la mezcla de concreto. Para ello como primer paso se identificó la cantera para la obtención de los agregados, dichos agregados fueron llevados al laboratorio de concreto de la Universidad Privada del Norte, en donde se realizaron los diferentes ensayos para determinar sus propiedades y de esta manera verificar que se encuentren dentro de los parámetros establecidos para poder realizar el diseño de mezclas patrón y determinar la cantidad de aditivo que se va a adicionar, ya sea de 2% y 4%, una vez obtenidos estos valores, se realizaron las probetas de concreto las cuales fueron 15 cm de alto x 10 cm de diámetro. Por cada porcentaje de aditivo se realizaron 24 probetas, obteniendo así 72 probetas en total, las cuales fueron ensayadas a los 7, 14, 21 y 28 días de curado, el ensayo que nos permitió determinar la permeabilidad del concreto, se realizó mediante un permeámetro que fue construido siguiendo cada uno de los pasos estipulados en el ACI 522r. Los resultados de cada ensayo fueron anotados en formatos de recolección de datos, que luego fueron procesados, obteniendo para 7 días de curado, valores de 0.000193 m/s para el concreto patrón, 0.000177 m/s para el concreto con 2% de aditivo plastificante y 0.000157 m/s para el concreto con 4% de aditivo plastificante. Para 14 días de curado, obtuvimos valores de 0.000149 m/s para el concreto patrón, 0.000132 m/s para el concreto con 2% de aditivo plastificante y 0.000120 m/s, para el concreto con 4% de aditivo plastificante, a los 21 días de curado, obtuvimos valores de 0.000109 m/s para el concreto patrón, 0.0000962 m/s para el concreto con 2% de aditivo plastificante y 0.0000870 m/s para el concreto con 4% de aditivo plastificante y para 28 días de curado, obtuvimos valores de 0.0000819 m/s para el concreto patrón, 0.0000578 m/s para el concreto con 2% de aditivo plastificante y 0.0000475 m/s para el concreto con 4% de aditivo plastificante, estos valores fueron clasificados en la NTC 4483, para su respectiva clasificación, además con estos valores obtenidos podemos decir que el aditivo plastificante disminuye la permeabilidad del concreto para 7 días de curado en un 8% y 19% con 2% y 4% de aditivo plastificante respectivamente, a los 14 días de curado presenta una disminución de 11% y 19% respectivamente, para 21 días de curado la permeabilidad disminuye en 12% y 20% y para 28 días de curado presenta una disminución de 29% para 2% de aditivo y 42% para 4% de aditivo.es_PE
dc.description.abstractABSTRACT Concrete is a material used in the construction of different types of buildings, in many cases the use of additives is recommended to improve some properties of concrete, between one of is to decrease the permeability thereof. That is why in this thesis is to investigate the permeability of concrete fc = 210 kg / cm2, for which additive was used Sika Cem Plasticizer in percentages of 2% and 4% were added to the mix concrete. To do this as a first step the quarry to obtain aggregates, these aggregates were taken to the laboratory concrete Private University of the North, where various tests were conducted to determine their properties are identified, and thus verify that are within the parameters established to perform the mix design pattern and determine the amount of additive to be added, either 2% and 4%, once obtained these values, concrete specimens were made which were 15 cm high x 10 cm diameter. For every percentage of additive 24 specimens were performed, obtaining 72 samples in total, which were tested at 7, 14, 21 and 28 days of curing, the test that allowed us to determine the permeability of concrete, was made using a permeameter which it was built, following each of the steps outlined in the ACI 522r. The results of each trial were recorded in formats of data collection, which were then processed, obtaining for 7 days cure, values of 0.000193 m / s for the specific pattern, 0.000177 m / s for concrete with 2% plasticizer additive and 0.000157 m / s for concrete with 4% plasticizer additive. For 14 days cure, we obtained values of 0.000149 m / s for the specific pattern, 0.000132 m / s for concrete with 2% plasticizer additive and 0.000120 m / s, for concrete with 4% plasticizer additive, at 21 days of curing, we obtained values of 0.000109 m / s for the specific pattern, 0.0000962 m / s for concrete with 2% plasticizer additive and 0.0000870 m / s for concrete with 4% plasticizer additive and 28 days of curing, obtained values of 0.0000819 m / s for the specific pattern, 0.0000578 m / s for concrete with 2% plasticizer additive and 0.0000475 m / s for concrete with 4% plasticizer additive, these values were classified in ISO 4483, for their relative rankings, in addition to these values obtained we can say that the plasticizing additive decreases concrete permeability for 7 days cure at 8% and 19% with 2% and 4% plasticizer additive respectively, at 14 days of curing presents a decrease of 11% and 19% respectively, for 21 days curing permeability decreases 12% and 20% in and cured for 28 days shows a decrease of 29% for 2% additive and 42% to 4% of additive.es_PE
dc.description.uriTesises_PE
dc.formatApplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de Américaes_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectPermeabilidades_PE
dc.subjectConcretoes_PE
dc.subjectMateriales de construcciónes_PE
dc.titlePermeabilidad de un concreto F’C = 210 KG/CM2 utilizando diferentes porcentajes de aditivo plastificante, Cajamarca, 2016es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeCajamarcaes_PE
renati.author.dni47376140
renati.discipline732016es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess