Mostrar el registro sencillo del ítem
Influencia en la resistencia a la compresión axial al sustituir parcialmente cemento Portland tipo I por diatomita en un concreto 𝑓𝑐 ′ = 210 𝑘𝑔/𝑐𝑚2, 2016
dc.contributor.advisor | Mosqueira Moreno, Miguel Ángel | |
dc.contributor.author | Ordoñez Malaver, Jhanina Katiusca | |
dc.date.accessioned | 2017-09-18T18:00:09Z | |
dc.date.available | 2017-09-18T18:00:09Z | |
dc.date.issued | 2016-06-01 | |
dc.identifier.citation | Ordoñez, J. K. (2016). Influencia en la resistencia a la compresión axial al sustituir parcialmente cemento Portland tipo I por diatomita en un concreto 𝑓𝑐 ′ = 210 𝑘𝑔/𝑐𝑚2, 2016 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/11020 | es_PE |
dc.identifier.other | 624 ORDO 2016 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/11020 | |
dc.description.abstract | RESUMEN En la presente tesis se ha determinado la influencia en la resistencia a compresión axial al sustituir parcialmente cemento Portland tipo I por Diatomita en un concreto 𝑓𝑐 ′ = 210 𝑘𝑔 𝑐𝑚2 La resistencia a compresión axial fue evaluada mediante la elaboración de especímenes de concreto que fueron ensayados a la edad de 28 días; para dar inicio a la investigación se determinó las propiedades de los agregados usados, evaluando las propiedades físico mecánicas según las normas ASTM / NTP, que establece los requisitos mínimos para ser usados en la elaboración concreto, también se realizó ensayos del concreto en estado fresco y endurecido, sobresaliendo el ensayo de resistencia a la compresión axial del concreto (ASTM C39 / NTP 339.034). La metodología de la investigación consistió en elaborar un diseño de mezclas de concreto siguiendo las recomendaciones de ACI 211, con una resistencia requerida de 𝑓𝑐 ′ = 210 𝑘𝑔 𝑐𝑚2 a la que denominé diseño patrón, a partir de este diseño elaboré 4 diseños para la investigación, a los que denominé diseños modificados, en estos diseños se realizó la sustitución parcial de cemento Portland tipo I por Diatomita en diferentes porcentajes 10%, 20% 30% y 40% respecto al peso del material cementante, manteniendo constante el peso del resto de materiales parte del diseño de mezcla ( agregados y agua), los diseños fueron plasmados en la elaboración de especímenes de concreto que luego fueron ensayados. Considerando los resultados obtenidos se concluye que existe una influencia positiva al sustituir parcialmente cemento Portland tipo I por Diatomita donde al sustituir 10% de cemento Portland tipo I por Diatomita se alcanza una resistencia a la compresión axial máxima de 𝑓𝑐 ′ = 210 𝑘𝑔 𝑐𝑚2 incrementándose un 7.73%. 2 | es_PE |
dc.description.abstract | ABSTRACT In this thesis it has been determined the influence on the resistance to axial compression to partially replace Portland cement type I by Diatomite in a concrete 𝑓𝑐 ′ = 210 𝑘𝑔 𝑐𝑚2 Axial compression resistance was evaluated by preparing concrete specimens were tested at the age of 28 days; to begin to research the properties of the aggregates used it was determined by evaluating the physical and mechanical properties according to ASTM / NTP standards, which sets minimum requirements for use in concrete manufacture, testing of concrete was also performed in fresh and hardened, standing the test of resistance to axial compression of concrete (ASTM C39 / NTP 339,034). The methodology of the research was to develop a concrete mix design following the recommendations of ACI 211, with a strength required of 𝑓𝑐 ′ = 210 𝑘𝑔 𝑐𝑚2 to which denominated design pattern from this design develop 4 designs for research, which denominated modified designs, in these designs the partial replacement of Portland cement type I 10% 20% 30% and 40% was held by Diatomite in different percentages based on the weight of cementitious material, keeping constant weight of other materials of the mix design (aggregates and water), the designs were reflected in the development of concrete specimens were then tested. Considering the results it is concluded that there is a positive influence to partially replace Portland cement type I by Diatomite where 10% when replacing Portland cement type I by Diatomite maximum resistance to axial compression 𝑓𝑐 ′ = 210 𝑘𝑔 𝑐𝑚2 isreached represented by 107.73%.2 | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/msword | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/closedAccess | es_PE |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Resistencia a la compresión | es_PE |
dc.subject | Concreto | es_PE |
dc.subject | Resistencia de materiales | es_PE |
dc.subject | Ingeniería Civil | es_PE |
dc.title | Influencia en la resistencia a la compresión axial al sustituir parcialmente cemento Portland tipo I por diatomita en un concreto 𝑓𝑐 ′ = 210 𝑘𝑔/𝑐𝑚2, 2016 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Cajamarca | es_PE |
renati.advisor.dni | 26733060 | |
renati.author.dni | 71251398 | |
renati.discipline | 732016 | es_PE |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis [1643]