Mostrar el registro sencillo del ítem

dc.contributor.advisorRavines Azañero, Irene Del Rosario
dc.contributor.authorAlemán Laura, Anthony Roswell
dc.date.accessioned2017-10-23T13:43:24Z
dc.date.available2017-10-23T13:43:24Z
dc.date.issued2017-10-05
dc.identifier.citationAlemán, A. R. (2017). Resistencia a compresión axial del mortero cemento – arena 1:4 con el reemplazo de vidrio molido (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/11191es_PE
dc.identifier.other624 ALEM 2017es_PE
dc.identifier.urihttps://hdl.handle.net/11537/11191
dc.description.abstractRESUMEN En el presente trabajo de investigación se ha realizado la comparación de la resistencia a compresión de un mortero cemento-arena con dosificación 1:4, con reemplazo parcial del cemento por vidrio molido pasante la malla N° 200 en tres porcentajes de 5%, 10% y 15%, se ha seleccionado la cantera Roca Fuerte ubicada en el distrito de Baños del Inca, de la cual se han analizado sus propiedades físicas determinándose que su granulometría está dentro de los límites de acuerdo a la norma ASTM C-33, su módulo de finura es 2.97, gravedad específica 2.621 gr/cm3 , absorción 2.775%, peso unitario suelto 1719.979 Kg/m3 , peso unitario compactado 1846.617 Kg/m3 y contenido de humedad 6.172%; así mismo, se verificó la finura del cemento Pacasmayo Extraforte ICO, encontrándose su valor de 12.27%, y del mismo modo se evaluó la finura del vidrio determinándose un valor de 1.40%; se ha propuesto 4 edades de curado: 24 horas, 3 días, 7 días y 28 días, registrándose que las resistencias promedio del mortero patrón son 22.01 kg/cm2 , 24.20 kg/cm2 , 128.78 kg/cm2 , 151.76 kg/cm2 , respectivamente, para el mortero con reemplazo del 5% se registró las resistencias promedios 20.36 kg/cm2 , 77.55 kg/cm2 , 156.73 kg/cm2 , 181.01 kg/cm2 ,respectivamente, para el mortero con reemplazo del 10% se registró las resistencias promedios 15.32 kg/cm2 , 56.79 kg/cm2 , 106.86 kg/cm2 , 142.32 kg/cm2 , respectivamente; y por último para el mortero con reemplazo del 15% se registró las resistencias promedios 20.88 kg/cm2 , 65.70 kg/cm2 , 112.09 kg/cm2 , 138.36 kg/cm2 ; llegando a determinar que a mayor incorporación de vidrio molido como reemplazo del cemento disminuye la resistencia a compresión axial, sin embargo también se identificó a su vez que las máxima resistencia obtenida es con el reemplazo de 5% logrando incluso superar la resistencia a compresión axial de la probeta patrón.es_PE
dc.description.abstractABSTRACT In the present work the comparison of the compressive strength of a cement-sand mortar with a 1:4 dosage, with partial replacement of the cement by grinding glass through the mesh N° 200 in three percentages of 5%, 10% and 15%, has selected the Roca Fuerte quarry located in the district of Baños del Inca, whose physical properties have been analyzed determining that their granulometry is within the limits according to ASTM C33, its module of fineness is 2.97, specific gravity 2.621 gr/cm3 , absorption 2.775%, unit weight loose 1719.979 kg/m3 , compacted unit weight 1846.617 kg/m3 and moisture content 6.172%; In addition, the fineness of the Pacasmayo Extraforte ICO cement was verified, its value being 12.27%, and the fineness of the glass was also evaluated, determining a value of 1.40%; it has been proposed 4 curing ages: 24 hours, 3 days, 7 days and 28 days, with the average resistance of the standard mortar being 22.01 kg/cm2 , 24.20 kg/cm2 , 128.78 kg/cm2 , 151.76 kg/cm2 , respectively , for the mortar with 5% replacement the average resistance was recorded 20.36 kg/cm2 , 77.55 kg/cm2 , 156.73 kg/cm2 , 181.01 kg/cm2 respectively, for the mortar with 10% replacement the average resistance was recorded 15.32 kg/cm2 , 56.79 kg/cm2 , 106.86 kg/cm2 , 142.32 kg/cm2 , respectively; and finally for the mortar with replacement of 15% the average resistance was recorded 20.88 kg/cm2 , 65.70 kg/cm2 , 112.09 kg/cm2 , 138.36 kg/cm2 ; arriving to determine that the greater incorporation of ground glass as a replacement of the cement decreases the resistance to axial compression, however it was also identified in turn that the maximum resistance obtained is with the replacement of 5% even managing to overcome the resistance to axial compression of the standard test piece.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectResistencia a la compresiónes_PE
dc.subjectVidrioes_PE
dc.subjectCementoes_PE
dc.titleResistencia a compresión axial del mortero cemento – arena 1:4 con el reemplazo de vidrio molidoes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeCajamarcaes_PE
renati.advisor.dni40208212
renati.author.dni73021915
renati.discipline732016es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess