Mostrar el registro sencillo del ítem

dc.contributor.advisorFarfán Chilicaus, Gary Christiam
dc.contributor.authorSaucedo Chávez, José Genaro
dc.contributor.authorTorres Medina, Alexander Antenor
dc.date.accessioned2017-11-09T13:58:20Z
dc.date.available2017-11-09T13:58:20Z
dc.date.issued2017-08-11
dc.identifier.citationSaucedo, J. G., & Torres, A. A. (2017). Influencia de la relación masa de resina / volumen Dam y tiempo de agitación sobre la remoción de hierro total, utilizando resinas iónicas de efluentes de la zona de Hualgayoc, Cajamarca 2017 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/11325es_PE
dc.identifier.other622 SAUC 2017es_PE
dc.identifier.urihttps://hdl.handle.net/11537/11325
dc.description.abstractRESUMEN Se estudió la influencia de la relación masa de resina / volumen DAM y tiempo de agitación sobre la remoción de hierro total, utilizando resinas iónicas de efluentes de la zona de Hualgayoc, Cajamarca. El estudio experimental se realizó en un vaso de precipitación, utilizando efluente con diferentes relaciones de masa de resina / volumen DAM en función de tiempos de agitación a 1 hora, 3 horas y 5 horas, con una ley de 1253.2 ppm de hierro. El resultado del estudio del empleo de resinas iónicas concluyó que la remoción de hierro a 1 hora y 0.025 g resina / ml DAM fue de 8.78 % y a medida que ambas variables aumentaban, la remoción también aumentaban, es así que se llegó obtener una remoción de 99.01 % a 5 horas y 0.100 g resina / ml DAM. Los resultados son confirmados mediante análisis de varianza para un nivel de confianza de 95%. De esto se concluye que la remoción de hierro por la influencia del tiempo de agitación es de F 0 = 67941.4507 es mayor a F 0.05,2.35 = 3.4028, y la influencia de la masa de resina / volumen DAM, el F 0 = 191273.0043 es mayor a F 0.05,3.35 = 3.0088 y con la influencia del tiempo de residencia y la masa de resina / volumen DAM es de F 0 = 15272.7602, la cual es mayor a F 0.05,6,35 = 2.5082, obtenido de manera tabular. Esto confirma la aceptación de la hipótesis alterna, por lo tanto, la influencia del tiempo de residencia y la relación masa de resina / volumen DAM de manera individual como en conjunto si afectan significativamente en la remoción de hierro.es_PE
dc.description.abstractABSTRACT The influence of resin mass / volume DAM ratio and agitation time on total iron removal was studied, using ionic resins of effluents from the Hualgayoc area, Cajamarca. The experimental study was performed in a beaker, using effluent with different resin mass / DAM volume ratios as a function of stirring times at 1 hour, 3 hours and 5 hours, with a law of 1253.2 ppm of iron. The results of the study of the use of ionic resins concluded that the removal of iron at 1 hour and 0.025 g resin / ml DAM was 8.78% and as both variables increased, the removal also increased, so a removal of 99.01% at 5 hours and 0.100 g resin / ml DAM. The results are confirmed by analysis of variance for a confidence level of 95%. From this it is concluded that the removal of iron by the influence of the agitation time is F 0 = 67941.4507 is greater than F 0.05,2.35 = 3.4028, and the influence of the mass of resin / volume DAM, F 0 = 191273.0043 is greater At F 0.05.3.35 = 3.0088 and with the influence of residence time and the mass of resin / DAM volume is F 0 = 15272.7602, which is greater than F 0.05,6,35 = 2.5082, obtained in a tabular manner. This confirms the acceptance of the alternating hypothesis, therefore, the influence of residence time and the resin mass / DAM volume ratio individually as a whole if they significantly affect the removal of iron.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/closedAccesses_PE
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectMineríaes_PE
dc.subjectAguaes_PE
dc.subjectCalidad del aguaes_PE
dc.titleInfluencia de la relación masa de resina / volumen Dam y tiempo de agitación sobre la remoción de hierro total, utilizando resinas iónicas de efluentes de la zona de Hualgayoc, Cajamarca 2017es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería de Minases_PE
thesis.degree.nameIngeniero de Minases_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.07.05es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeCajamarcaes_PE
renati.advisor.dni41603429
renati.author.dni26672784
renati.author.dni41004478
renati.discipline724026es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem