Mostrar el registro sencillo del ítem

dc.contributor.advisorRavines Azañero, Irene del Rosario
dc.contributor.authorCholán De La Cruz, Julio Ulises
dc.date.accessioned2018-01-26T21:30:28Z
dc.date.available2018-01-26T21:30:28Z
dc.date.issued2018-01-05
dc.identifier.citationCholán, J. U. (2016). Efecto de tres niveles de PET reciclado como reemplazo de agregado fino en la resistencia a compresión axial del concreto convencional f’c 210 kg/cm2 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/12667es_PE
dc.identifier.other624.1834 CHOL 2016es_PE
dc.identifier.urihttps://hdl.handle.net/11537/12667
dc.description.abstractLa presente investigación tiene como objetivo determinar la resistencia a compresión axial reemplazando el agregado fino por PET reciclado en 5%, 10% y 15% en un concreto convencional f’c = 210 kg/cm según la NTP 339.034 HORMIGON CONCRETO (2008). Para este estudio se utilizó agregados de la cantera “Bazán”, ubicada salida a Bambamarca a la altura del grifo 3M y cemento Portland tipo I, Se evaluó las propiedades físico-mecánicas de los agregados usados, los cuales presentan los siguientes valores: módulo de finura 2.98, gravedad específica 2.59 gr/cm 2 , absorción 0.911%, peso unitario suelto 1729 kg/m 3 , peso unitario compactado 1832 kg/m y contenido de humedad 6.60% para agregado fino, de la misma manera para el agregado grueso su módulo de finura es 6.99, gravedad específica 2.64 gr/cm 3 3 3 , absorción 1.64%, peso unitario suelto 1460 kg/m , peso unitario compactado 1526 kg/m y contenido de humedad 0.76%, cumplen con las especificaciones en la norma ASTM C33-NTP 400.037. Se realizó el diseño de concreto mediante el método ACI del Comité 211 para un f’c= 210 kg/cm 3 muestra patrón y 3 muestras con diferentes porcentajes de PET reciclado 5%, 10% y 15% reemplazando el agregado fino, evaluados en 3 periodos de curado 7, 14 y 28 días; determinándose que a 7 días de curado la resistencia alcanzada fue de 144.38 kg/cm 2 con 0% de PET reciclado; 138 kg/cm 2 2 al reemplazar 5% de PET; 131.13 kg/cm al reemplazar 10% de PET y 123.39 kg/cm al reemplazar 15% de PET reciclado; a los 14 días de curado la resistencia alcanzada fue de 181.23 kg/cm 2 2 con 0% de PET reciclado; 176.06 kg/cm al reemplazar 5% de PET; 170.64 kg/cm 2 al reemplazar 10% de PET y 164.91 kg/cm al reemplazar 15% de PET reciclado; para un tiempo de 28 días de curado la resistencia alcanzada fue de 211.21 kg/cm 2 con 0% de PET reciclado; 204.72 kg/cm 2 2 al reemplazar 5% de PET; 195.31 kg/cm al reemplazar 10% de PET y 187.20 kg/cm al reemplazar 15% de PET reciclado. Finalmente se concluye que la resistencia a compresión axial respecto al concreto patrón de los ensayos realizados a los 28 días de curado disminuye con la utilización del 5% PET reciclado en un 5.28 kg/cm 2 , con la utilización del 10% PET reciclado, disminuye un 14.69 kg/cm y con la utilización del 15% PET reciclado, disminuye un 22.80 kg/cm 2 2 ; evidenciándose que disminuyen en 3.07%, 7.53% y 11.37% conforme aumenta el porcentaje de PET reciclado en 5, 10 y 15% respectivamente.es_PE
dc.description.abstractThe objective of this research is to determine the axial compressive strength that replaces the fine aggregate with recycled PET at 5%, 10% and 15% in conventional f'c = 210 kg/cm according to NTP 339.034 CONCRETE (2008). For this study the aggregates of the quarry "Bazán", Salida a Bambamarca at the height of the tap 3M and Portland cement type I, were used. The physicalmechanical properties of the used aggregates were evaluated. The values are presented: Module fineness 2.98, specific gravity 2.59 gr/cm 3 2 , absorption 0.911%, loose unit weight 1729 kg/m , compacted unit weight 1832 kg/m and moisture content 6.60% for fine aggregate, in the same way for coarse aggregate its fineness modulus is 6.99 , specific gravity 2.64 gr/cm 3 , absorption 1.64%, loose unit weight 1460 kg/m 3 , compacted unit weight 1526 kg/m 3 3 and moisture content 0.76%, complies with the specifications in ASTM C33-NTP 400.037. The concrete design was carried out using the ACI method of Committee 211 for a f'c = 210 kg/cm standard sample and 3 samples with different percentages of PET recycled 5%, 10% and 15% replacing the fine aggregate, evaluated in 3 Curing periods 7, 14 and 28 days; determining that after 7 days of curing the resistance reached was 144.38 kg/cm 2 with 0% recycled PET; 138 kg/cm 2 2 when replacing 5% PET; 131.13 kg/cm when replacing 10% PET and 123.39 kg/cm when replacing 15% recycled PET; after 14 days of curing the resistance reached was 181.23 kg/cm 2 2 with 0% recycled PET; 176.06 kg/cm when replacing 5% PET; 170.64 kg/cm 2 when replacing 10% PET and 164.91 kg/cm 2 2 when replacing 15% recycled PET; for a time of 28 days of curing the resistance reached was 211.21 kg/cm with 0% recycled PET; 204.72 kg/cm 2 when replacing 5% PET; 195.31 kg/cm when replacing 10% PET and 187.20 kg/cm 2 2 when replacing 15% recycled PET. Finally, it is concluded that the resistance to axial compression with respect to concrete, standard of the tests carried out, after 28 days of curing, decreases with the use of 5%, recycled PET at 5.28 kg/cm , with the use of 10%, recycled PET, decreases by 14.69 kg/cm 2 2 and with the use of 15% of recycled PET, with a decrease of 22.80 kg/cm ; evidencing that they decrease by 3.07%, 7.53% and 11.37% as the percentage of recycled PET increases by 5, 10 and 15% respectively.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de Américaes_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectReciclajees_PE
dc.subjectPlásticoses_PE
dc.subjectResistencia a la compresiónes_PE
dc.subjectConcretoes_PE
dc.titleEfecto de tres niveles de PET reciclado como reemplazo de agregado fino en la resistencia a compresión axial del concreto convencional f’c 210 kg/cm2es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeCajamarcaes_PE
renati.advisor.dni40208212
renati.advisor.orcidhttps://orcid.org/0000-0003-4203-7795es_PE
renati.author.dni70018534
renati.discipline732016es_PE
renati.jurorAguilar Aliaga, Orlando
renati.jurorQuispe Rodríguez, Gerson
renati.jurorAlva Sarmiento, Anita Elizabet
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess