Show simple item record

dc.contributor.advisorVásquez Díaz, Alberto Rubén
dc.contributor.authorChávez Silva, Ana Felicitas
dc.date.accessioned2019-05-10T14:16:32Z
dc.date.available2019-05-10T14:16:32Z
dc.date.issued2019-04-17
dc.identifier.citationChávez, A. F. (2019). Influencia del tamaño de vidrio molido en la resistencia a compresión del concreto, Trujillo 2019 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/21164es_PE
dc.identifier.other624.1838 CHAV 2019es_PE
dc.identifier.urihttps://hdl.handle.net/11537/21164
dc.description.abstractLa investigación, tiene como objetivo determinar la influencia del tamaño de vidrio molido sobre la resistencia a compresión del concreto, reduciendo la contaminación utilizando residuos de vidrio. Se plantea el uso del vidrio residual como una alternativa para la elaboración del concreto, reemplazando el 30%, 40%, 50% y 60% para cada tamaño de agregado fino por los mismos porcentajes y tamaño de vidrio molido, con una relación de agua/cemento de 0.56. Se utilizó agregado fino con un módulo de finura de 2.71, cemento Pacasmayo Tipo I. Se realizaron los ensayos de caracterización para los agregados tales como granulometría, contenido de humedad, peso unitario suelto y compactado, peso específico y absorción. Los especímenes para el ensayo a compresión fueron cilíndricos de 4” de diámetro y 8” de altura. El diseño más óptimo se dio con el 60% de vidrio de la malla #8 sustituyendo por ese porcentaje y tamaño de agregado fino, con valores de una resistencia promedio a los 7 días de 205 kg/cm2 y a los 28 días con una resistencia promedio de 249 kg/cm2. Mientras más porcentaje de vidrio del tamaño de la abertura de la malla #8 reemplazando al agregado fino dio mejores resultados de resistencia a compresión.es_PE
dc.description.abstractThe objective of the investigation is to determine the influence of the size of the ground glass on the compressive strength of the concrete, reducing the contamination using glass waste. The use of waste glass as an alternative to the manufacture of concrete is proposed, replacing 30%, 40%, 50% and 60% for each size of fine aggregate by the same percentages and size of ground glass, with a water / cement ratio of 0.56. Fine aggregate was used with a fineness modulus of 2.71, Pacasmayo Type I cement. Characterization tests were performed for aggregates such as granulometry, moisture content, loose and compacted unit weight, specific weight and absorption. The specimens for the compression test were cylindrical 4" in diameter and 8" in height. The most optimal design was given with 60% glass of the # 8 mesh substituting for that percentage and size of aggregate, with values of an average resistance to the 7 days of 204.39 kg/cm2 and to the 28 days with an average resistance of 249.24 kg/cm2. The more percentage of glass in the # 8 mesh replacing the fine aggregate gave better compression resistance.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectConcreto/Hormigónes_PE
dc.subjectResistencia de materialeses_PE
dc.subjectVidrioes_PE
dc.subjectResistencia a la compresión
dc.subjectConstrucción
dc.titleInfluencia del tamaño de vidrio molido en la resistencia a compresión del concreto, Trujillo 2019es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeTrujillo San Isidroes_PE
renati.advisor.dni40385695
renati.advisor.orcidhttps://orcid.org/0000-0001-9018-5763
renati.author.dni75063631
renati.discipline732016es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess