dc.contributor.advisor | Díaz García, Gonzalo Hugo | |
dc.contributor.author | Velásquez Sinche, Ryan Halley | |
dc.date.accessioned | 2021-03-02T20:28:24Z | |
dc.date.available | 2021-03-02T20:28:24Z | |
dc.date.issued | 2020-11-25 | |
dc.identifier.citation | Velásquez, R. H. (2020). Análisis comparativo de las resistencias a la flexión y a la compresión entre el concreto tradicional y el concreto con añadido de aserrín al 5%, 10% y 15% según la norma ACI, Lima - 2020 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/25110 | es_PE |
dc.identifier.other | 624.1834 VELA 2020 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/25110 | |
dc.description.abstract | El objeto de este trabajo es analizar de manera comparativa las resistencias a la flexión y
compresión entre concreto tradicional y el concreto con añadido de aserrín al 5%, 10% y
15% según la norma ACI 211. Para la metodología, por tratarse de una investigación pseudo - experimental, la población es la misma que la muestra, constituida por un conjunto de 36 probetas
cilíndricas de concreto de 4” x 8” diseñadas y ensayadas bajo las normas NTP 339.034 y
8 muestras prismáticas 6” x 6” x 12” para ensayo a flexión algunas diseñadas de manera
convencional y otras diseñadas con aserrín añadido en 5%, 10% y 15% en peso de
cemento. Los resultados del laboratorio mostraron un aumento significativo de la resistencia
a la flexión al añadir 5% y 10% de aserrín a la mezcla convencional, asimismo , no existe
un aumento significativo de la resistencia a la compresión al añadir 5%, 10% ni 15% de
aserrín a la mezcla convencional, para corroborar lo antes mencionado se realizó la
prueba de Hipótesis t-Student con un nivel de significancia del 5% en el programa
estadístico IBM SPSS V.25. Con los resultados se concluyó que la mejor opción es el concreto con añadido de 5% de aserrín, ya que sus propiedades a la compresión y abrasión no difiere respecto al
concreto, pero mejora sus propiedades a la flexión respecto a la misma. | es_PE |
dc.description.abstract | The purpose of this work is to analyze in a comparative way the resistance to
bending and compression between traditional concrete and concrete with added sawdust
at 5%, 10% and 15% according to the ACI 211 standard. For the methodology, as it is a pseudo - experimental investigation, the population is the same as the sample, consisting of a set of 36 4 "x 8" cylindrical concrete test tubes designed and tested under the NTP 334 / NTP 339 standards. designed in a conventional way and others designed with sawdust added in 5%, 10% and 15% by weight of cement.
Laboratory results showed a significant increase in flexural strength when adding
5% sawdust to the conventional mix, likewise, there is no significant increase in
compressive strength when adding 5%, 10% or 15% sawdust to the conventional mix and
as there is no significant wear when the addition is 5% sawdust, for the additions of 10%
and 15% the wear of the experimental concrete is high, to corroborate the
aforementioned, the Hypothesis t test was carried out -Student with a significance level
of 5% in the statistical program IBM SPSS V.25. With the results, it was concluded that the best option is concrete with an addition of 5% sawdust, since its compression and abrasion properties do not differ from concrete, but it improves its flexural properties with respect to it. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.format | application/msword | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Concreto | es_PE |
dc.subject | Resistencia a la compresión | es_PE |
dc.subject | Materiales de construcción | es_PE |
dc.title | Análisis comparativo de las resistencias a la flexión y a la compresión entre el concreto tradicional y el concreto con añadido de aserrín al 5%, 10% y 15% según la norma ACI, Lima - 2020 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Los Olivos | es_PE |
renati.advisor.dni | 40539624 | |
renati.advisor.orcid | https://orcid.org/0000-0002-3441-8005 | es_PE |
renati.author.dni | 43342608 | |
renati.discipline | 732016 | es_PE |
renati.juror | Poma Zumarán, Aldo Juan | |
renati.juror | Verau Miranda, Edmundo | |
renati.juror | Salas Paulet, Manuel Jesús | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |