dc.identifier.citationVelásquez, R. H. (2020). Análisis comparativo de las resistencias a la flexión y a la compresión entre el concreto tradicional y el concreto con añadido de aserrín al 5%, 10% y 15% según la norma ACI, Lima - 2020 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/25110es_PE
dc.identifier.other624.1834 VELA 2020es_PE
dc.identifier.urihttps://hdl.handle.net/11537/25110
dc.description.abstractEl objeto de este trabajo es analizar de manera comparativa las resistencias a la flexión y compresión entre concreto tradicional y el concreto con añadido de aserrín al 5%, 10% y 15% según la norma ACI 211. Para la metodología, por tratarse de una investigación pseudo - experimental, la población es la misma que la muestra, constituida por un conjunto de 36 probetas cilíndricas de concreto de 4” x 8” diseñadas y ensayadas bajo las normas NTP 339.034 y 8 muestras prismáticas 6” x 6” x 12” para ensayo a flexión algunas diseñadas de manera convencional y otras diseñadas con aserrín añadido en 5%, 10% y 15% en peso de cemento. Los resultados del laboratorio mostraron un aumento significativo de la resistencia a la flexión al añadir 5% y 10% de aserrín a la mezcla convencional, asimismo , no existe un aumento significativo de la resistencia a la compresión al añadir 5%, 10% ni 15% de aserrín a la mezcla convencional, para corroborar lo antes mencionado se realizó la prueba de Hipótesis t-Student con un nivel de significancia del 5% en el programa estadístico IBM SPSS V.25. Con los resultados se concluyó que la mejor opción es el concreto con añadido de 5% de aserrín, ya que sus propiedades a la compresión y abrasión no difiere respecto al concreto, pero mejora sus propiedades a la flexión respecto a la misma.es_PE
dc.description.abstractThe purpose of this work is to analyze in a comparative way the resistance to bending and compression between traditional concrete and concrete with added sawdust at 5%, 10% and 15% according to the ACI 211 standard. For the methodology, as it is a pseudo - experimental investigation, the population is the same as the sample, consisting of a set of 36 4 "x 8" cylindrical concrete test tubes designed and tested under the NTP 334 / NTP 339 standards. designed in a conventional way and others designed with sawdust added in 5%, 10% and 15% by weight of cement. Laboratory results showed a significant increase in flexural strength when adding 5% sawdust to the conventional mix, likewise, there is no significant increase in compressive strength when adding 5%, 10% or 15% sawdust to the conventional mix and as there is no significant wear when the addition is 5% sawdust, for the additions of 10% and 15% the wear of the experimental concrete is high, to corroborate the aforementioned, the Hypothesis t test was carried out -Student with a significance level of 5% in the statistical program IBM SPSS V.25. With the results, it was concluded that the best option is concrete with an addition of 5% sawdust, since its compression and abrasion properties do not differ from concrete, but it improves its flexural properties with respect to it.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectConcretoes_PE
dc.subjectResistencia a la compresiónes_PE
dc.subjectMateriales de construcciónes_PE
dc.titleAnálisis comparativo de las resistencias a la flexión y a la compresión entre el concreto tradicional y el concreto con añadido de aserrín al 5%, 10% y 15% según la norma ACI, Lima - 2020es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeLos Olivoses_PE
renati.advisor.dni40539624
renati.advisor.orcidhttps://orcid.org/0000-0002-3441-8005es_PE
renati.author.dni43342608
renati.discipline732016es_PE
renati.jurorPoma Zumarán, Aldo Juan
renati.jurorVerau Miranda, Edmundo
renati.jurorSalas Paulet, Manuel Jesús
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess