Mostrar el registro sencillo del ítem

dc.contributor.advisorTello Malpartida, Omar Demetrio
dc.contributor.authorCampos Pizarro, Juan Eduardo
dc.contributor.authorIbañez Minaya, Kevin Abel
dc.date.accessioned2022-10-03T23:06:49Z
dc.date.available2022-10-03T23:06:49Z
dc.date.issued2022-08-13
dc.identifier.citationCampos, J. E., & Ibañez, K. A. (2022). Comportamiento no lineal de los sistemas estructurales Emmedue y muro de ductilidad limitada aplicada al Hotel Costa Blanca - Vichayito - Piura 2022 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/31441es_PE
dc.identifier.other624.1 CAMP 2022es_PE
dc.identifier.urihttps://hdl.handle.net/11537/31441
dc.description.abstractEl trabajo de investigación tuvo como objetivo determinar la influencia de los sistemas estructurales Emmedue y Muros de Ductilidad Limitada en el comportamiento no lineal del hotel Costa Blanca ubicado en Vichayito, Piura; el tipo de investigación fue aplicada, cuantitativa, de nivel explicativa, con un diseño cuasi experimental; la población estuvo conformada por las edificaciones para hoteles cuyo sistema estructural este basado en Emmedue o Muros de Ductilidad Limitada en Vichayito, Piura; mientras que la muestra estuvo constituida por el hotel Costa Blanca la cual será analizada bajo los sistemas Emmedue y Muros de Ductilidad Limitada. Con la ayuda del programa Etabs V19, se modelizó la edificación para ambos sistemas con la finalidad de poder conocer el comportamiento no lineal estático de la estructura, obteniendo los siguientes resultados: El sistema Emmedue presento una distorsión máxima inelástica de 0.00017, con un punto de desempeño y una ductilidad de 3.5 cm y 24.33 respectivamente, encontrándose dentro de un nivel de desempeño operacional, además de una capacidad de sobrerresistencia de 1.13; mientras que el sistema MDL presenta una distorsión máxima de 0.00012, con un punto de desempeño y una ductilidad de 1.28 cm y 22.58 respectivamente, encontrándose dentro del nivel de desempeño operacional, además de una capacidad de sobrerresistencia de 1.62. De este modo se concluyó que el sistema de Muros de Ductilidad Limitada tendrá una mayor influencia para su comportamiento no lineal.es_PE
dc.description.abstractThe research work aimed to determine the influence of structural systems Emmedue and Limited Ductility Walls on the non-linear behavior of the hotel Costa Blanca located in Vichayito, Piura; the type of research was applied, quantitative, explanatory level, with a quasi-experimental design; the population was made up of buildings for hotels whose structural system is based on Emmedue or Limited Ductility Walls in Vichayito, Piura; while the sample was constituted by the Costa Blanca hotel to which it will be analyzed under the systems Emmedue and Limited Ductility Walls. With the help of the Etabs V19 program, the building was modeled for both systems in order to be able to know the static nonlinear behavior of the structure, obtaining the following results: The Emmedue system presented a maximum inelastic distortion of 0.00017, with a performance point and ductility of 3.5 cm and 24.33 respectively, being within an operational performance level, in addition to an overresistance capacity of 1.13; while the Limited Ductility Walls system has a maximum distortion of 0.00012, with a performance point and ductility of 1.28 cm and 22.58 respectively, being within the level of operational performance, in addition to an overresistance capacity of 1.62. Thus, it was concluded that: In this way it was concluded that the system of Walls of Limited Ductility will have a greater influence on the influence for its non-linear behavior.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectDiseño sísmico de edificioses_PE
dc.subjectAnálisis sísmico de edificioses_PE
dc.subjectDiseño estructurales_PE
dc.subjectComportamiento no lineales_PE
dc.subjectEmmeduees_PE
dc.subjectMDLes_PE
dc.subjectPushoveres_PE
dc.subjectNonlinear behaviores_PE
dc.titleComportamiento no lineal de los sistemas estructurales Emmedue y muro de ductilidad limitada aplicada al Hotel Costa Blanca - Vichayito - Piura 2022es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeLos Olivoses_PE
renati.advisor.dni08644876
renati.advisor.orcidhttps://orcid.org/0000-0002-5043-6510es_PE
renati.author.dni74026016
renati.author.dni47564889
renati.discipline732016es_PE
renati.jurorQuesada Llanto, Julio
renati.jurorVega Rivera, Gerson
renati.jurorVildoso Flores, Alejandro
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess