dc.contributor.author | Alvarado, Jackeline | |
dc.contributor.author | Ocas, Rafael | |
dc.contributor.author | Cáceres Pérez, Shonel | |
dc.date.accessioned | 2023-10-13T17:01:57Z | |
dc.date.available | 2023-10-13T17:01:57Z | |
dc.date.issued | 2021-09-08 | |
dc.identifier.citation | Alvarado, J., Ocas, R., & Cáceres, S. (2021). Hydrogeological characterization by means of geometric electrical tomography (TGE) for the identification of aquifers in the Ronquillo Sector, Cajamarca - 2020 [Caracterización hidrogeológica mediante tomografías geoeléctricas (TGE) para la identificación de acuíferos en el sector Ronquillo, Cajamarca - 2020]. Proceedings of the LACCEI International Multi-conference for Engineering, Education and Technology, 2021-July(133), 1-6. http://dx.doi.org/10.18687/LACCEI2021.1.1.133 | es_PE |
dc.identifier.other | . | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/34422 | |
dc.description.abstract | El objetivo de este trabajo fue determinar el
potencial acuífero de las unidades litoestratigráficas en el Sector
Ronquillo, Cajamarca, el cual presenta escasez de agua. Para ello se
aplicó el método de tomografías eléctricas (TGE). El TGE se aplicó
utilizando la técnica de configuración Dipolo-Dipolo para poder
determinar la resistividad y poder delimitar los posibles acuíferos. Se
realizó 4 líneas (L-1, L-2, L-3, L-4), esta información fue analiza en
el Software Geosoft Oasis Montaj, logrando identificarse 4 capas
geoelectricas. Los resultados de las interpretaciones muestran un
potencial Acuífero en las capas 1 y 2 de las líneas 1 hasta 4 las cuales
se correlacionan geologicalmente con rocas volcánicas de la
Formación San Pablo (Tobas), las cuales presenta saturación alta
de presencia de agua. | es_PE |
dc.description.abstract | The objective of this work was to determine the aquifer potential
of the lithostratigraphic units in the Ronquillo Sector, Cajamarca,
which presents water shortages. For this, the method of electrical
tomography (TGE) was applied. The TGE was applied using the
Dipole-Dipole configuration technique to determine the resistivity
and to delimit the possible aquifers. 4 lines (L-1, L-2, L-3, L-4) were
made, this information was analyzed in the Geosoft Oasis Montaj
Software, managing to identify 4 geoelectric layers. The results of
the interpretations show an Aquifer potential in layers 1 and 2 of
lines 1 to 4, which are geologically correlated with volcanic rocks of
the San Pablo Formation (Tobas), which present high saturation of
the presence of water. | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Latin American and Caribbean Consortium of Engineering Institutions | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Acuíferos | es_PE |
dc.subject | Prospección geofísica | es_PE |
dc.subject | Teledetección | es_PE |
dc.subject | Petrología | es_PE |
dc.subject | Tomografías geoeléctricas | es_PE |
dc.subject | Aquifer | es_PE |
dc.subject | Geometric electrical tomography | es_PE |
dc.subject | Lithology | es_PE |
dc.title | Hydrogeological characterization by means of geometric electrical tomography (TGE) for the identification of aquifers in the Ronquillo Sector, Cajamarca - 2020 [Caracterización hidrogeológica mediante tomografías geoeléctricas (TGE) para la identificación de acuíferos en el sector Ronquillo, Cajamarca - 2020] | es_PE |
dc.type | info:eu-repo/semantics/conferenceObject | es_PE |
dc.publisher.country | PE | es_PE |
dc.identifier.journal | Proceedings of the LACCEI International Multi-conference for Engineering, Education and Technology | es_PE |
dc.description.peer-review | Revisión por pares | |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.07.01 | es_PE |
dc.description.sede | Cajamarca | es_PE |
dc.identifier.doi | http://dx.doi.org/10.18687/LACCEI2021.1.1.133 | |