Aprovechamiento del sedimento proveniente de la planta de tratamiento de aguas ácidas, mezclado con arena limosa y arcilla en la obtención de un suelo de baja permeabilidad para el cierre del sector este del depósito de material inadecuado de Minera La Zanja, abril 2015

Fecha
2016-02-25Autor(es)
Alvitez Yeckle, Silvia del Pilar
Bravo Corrales, Rudecindo
Metadatos
Mostrar el registro completo del ítemResumen
RESUMEN
El siguiente trabajo de investigación hace referencia a distintos ensayos de suelos en
laboratorio y campo, realizados con el objetivo de buscar el aprovechamiento del
sedimento generado en la Planta de Tratamiento de Aguas Ácidas de Minera la Zanja
mezclado con arena limosa y arcilla para lograr un suelo de baja permeabilidad útil en el
cierre del Depósito de Material Inadecuado.
El estudio se ha enfocado en las especificaciones técnicas, dadas por Knight Piésold,
quien indica valores para huso granulométrico, límites de consistencia mínimo de 15,
porcentaje de compactación de 95%, contenido de humedad de -2 a +3%, y el coeficiente
de permeabilidad no mayor a 1x10
cm/s; como factores determinantes para obtener un
suelo de baja permeabilidad.
La investigación inició en laboratorio, ensayando cada tipo de suelo (sedimento, arena
limosa y arcilla) de manera individual para luego ser mezclados a diferentes
proporciones, de acuerdo a los resultados, se obtuvo la siguiente proporción: 20% de
sedimento, 40% de arena limosa, 40% de arcilla.
La mezcla obtenida en laboratorio se llevó a campo y se extendió en un área de 15 x 10
m
-6
2
en el Depósito de Material Inadecuado (DMI) con una compactación al 95% de la
máxima densidad seca; a un espesor de 200 mm, en la cual se pudo determinar la
Densidad de Campo y Permeabilidad del suelo.
Los ensayos de laboratorio y campo se realizaron según procedimientos de las normas
internacionales ASTM (American Society for Testing Materials).
Los resultados obtenidos son: índice de plasticidad (IP) 23, determinado según ASTM
D4318; coeficiente de permeabilidad 7.8×10
cm/s, determinado según Manual de
Drenaje USBR; compactación al 97.5 % de la máxima densidad seca, determinada según
ASTM D698; contenido de humedad óptimo en laboratorio fue 32.1%, en campo 34.05%
estando dentro del rango -2 a +3% indicadas en las especificaciones técnicas. De esta
manera determinamos la viabilidad de nuestra hipótesis que busca el aprovechamiento
del sedimento proveniente de la Planta de Tratamiento de Aguas Ácidas mezclado con
arena limosa y arcilla para obtener un suelo de baja permeabilidad útil en el cierre de
mina.
Mostrar más
ABSTRACT
The following work of investigation refers to different tests of soils in laboratory and field
they were realized with the aim to look for the utilization of the sediment generated in the
Acid Water Treatment Plant of Minner La Zanja mixed with slimy sand and clay to achieve
useful soil of low permeability in the closing of the Warehouse of Inadequate Material.
The study has focused in the technical specifications given by Knight Piésold, who
indicates values for granulometric spindle, consistency limits minimum of 15, percentage
of compaction of 95 %, range of dampness after the compaction-2 to +3 and coefficient of
permeability not major to 1x10-6 cm/s, as determinant factors to obtain a soil of low
permeability.
The investigation initiated in laboratory, testing every type of soil (sediment, slimy sand
and clay) in an individual way then they were mixed to different proportions, in agreement
to the results, the following proportion was obtained: 20 % of sediment, 40 % of slimy
sand, 40 % of clay.
The mixture obtained in laboratory was removed to field and it was extended in an area of
15 x 10 m2 in the Warehouse of Inadequate Material (DMI) with a compaction to 95 % of
the maximum dry density; to a thickness of 200 mm, in which it was possible to determine
the Density of Field and Permeability of the soil. The laboratory test programs and field
were realized according to procedures of the international procedure ASTM (American
Society for Testing Materials).
The obtained results are: index of plasticity (IP) 23, determined according to ASTM
D4318; coefficient of permeability 7.8×10-6 cm/s, determined according to Drainage
manual USBR; compaction to 97.5 % of the maximum dry density, determined according
to ASTM D698; ideal content of dampness in laboratory was 32.1 %, in field 34.05 %
being inside the range-2 to +3 % indicated in the technical specifications. Hereby we
determine the viability of our hypothesis that looks for the utilization of the sediment from
the Acid Water Treatment Plant mixed with slimy sand and clay to obtain a useful soil of
low permeability in the closing mine.
Mostrar más
Cita bibliográfica
Alvitez, S., & Bravo, R. (2016). Aprovechamiento del sedimento proveniente de la planta de tratamiento de aguas ácidas, mezclado con arena limosa y arcilla en la obtención de un suelo de baja permeabilidad para el cierre del sector este del depósito de material inadecuado de Minera La Zanja, abril 2015 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/9953
Colecciones
- Tesis [590]
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Elaboración de estudio de mecánica de suelos en suelos arcillosos para determinar el tipo de cimentación en la I.E. Nuestra Señora del Rosario
Scipion Falla, Angelo Giusseppi (Universidad Privada del Norte, 2022-06-13)Acceso abiertoLos suelos expansivos de alta plasticidad a través de los años han ocasionado pérdidas materiales como económicas en toda la parte del mundo. Los suelos arcillosos tienden a tener cambios de volumen cuando son humedecidos, ... -
Determinación de la zona óptima para proyectar el crecimiento urbano en el barrio La Paccha de la ciudad de Cajamarca, según la capacidad de carga
Gutierrez Cubas, Sandra Melissa (Universidad Privada del Norte, 2017-05-26)Acceso abiertoRESUMEN El objetivo de esta investigación es determinar la zona óptima para proyectar el crecimiento urbano en el barrio La Paccha de la ciudad de Cajamarca, según la capacidad de carga. Para el desarrollo de esta ... -
Zonificación mediante el sistema unificado de clasificación de suelos (SUCS) y la capacidad portante del suelo, para viviendas unifamiliares en la expansión urbana del anexo Lucmacucho Alto - sector Lucmacucho, distrito de Cajamarca
Briones Alva, María Emérita; Irigoin Gonzales, Nelson Ulices (Universidad Privada del Norte, 2015-10-23)Acceso abiertoRESUMEN La presente tesis tuvo como objetivo zonificar el Anexo Lucmacucho Alto mediante la clasificación de suelos (SUCS) y la capacidad portante del suelo para viviendas unifamiliares en la expansión urbana del sector. ...