Mostrar el registro sencillo del ítem
Evaluation of the microbiological quality of the air in the area of influence of the Cajamarca solid waste treatment plant [Evaluación de la calidad microbiológica del aire en el área de influencia de la planta de tratamiento de residuos sólidos de Cajamarca]
dc.contributor.author | Mendoza, Luis | |
dc.contributor.author | Jambo, Luz | |
dc.contributor.author | Sánchez, Marco | |
dc.contributor.author | Velásquez Marín, Magda | |
dc.date.accessioned | 2021-06-17T16:18:32Z | |
dc.date.available | 2021-06-17T16:18:32Z | |
dc.date.issued | 2020-09-15 | |
dc.identifier.citation | Mendoza, L. ...[et al]. (2020). Evaluation of the microbiological quality of the air in the area of influence of the Cajamarca solid waste treatment plant [Evaluación de la calidad microbiológica del aire en el área de influencia de la planta de tratamiento de residuos sólidos de Cajamarca]. Proceedings of the LACCEI International Multi-conference for Engineering, Education and Technology, (489). https://doi.org/10.18687/LACCEI2020.1.1.489 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/26870 | |
dc.description.abstract | RESUMEN El objetivo de este trabajo fue determinar la calidad microbiológica del aire en el área de influencia de la planta de tratamiento de residuos sólidos de Cajamarca en el mes de septiembre del 2 018 y en el mes de marzo del 2 019; con la finalidad de demostrar si existe contaminación microbiológica. Obteniendo como resultado del monitoreo en el mes de septiembre del 2 018 un promedio general de 2 408 UFC⁄m3 y en el mes de marzo del 2 019 se obtuvo un promedio general de 1 472 UFC⁄m3. De acuerdo, a los valores obtenidos solamente en el mes de septiembre sobrepasa el estándar de calidad propuesto por la Administración de Seguridad y Salud Ocupacional (OSHA, 2 001) que establece un límite de 2 000 UFC⁄m3 | es_PE |
dc.description.abstract | ABSTRACT The objective of this work was to determine the microbiological quality of the air in the area of influence of the solid waste treatment plant of Cajamarca in the month of September 2 018 and in the month of March 2 019; in order to demonstrate whether there is microbiological contamination. We obtained a general average of 2 408 UFC⁄m3 as a result of the monitoring in September 2 018 and a general average of 1 472 UFC⁄m3 in March 2 019. obtained. According to the values obtained only in the month of September, it exceeds the quality standard proposed by the Occupational Safety and Health Administration (OSHA, 2,001), which establishes a limit of 2,000 CFU / m3. | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | LACCEI | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights | Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América | * |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Microbiología ambiental | es_PE |
dc.subject | Contaminación atmosférica | es_PE |
dc.subject | Aire | es_PE |
dc.subject | Evaluación del impacto ambiental | es_PE |
dc.title | Evaluation of the microbiological quality of the air in the area of influence of the Cajamarca solid waste treatment plant [Evaluación de la calidad microbiológica del aire en el área de influencia de la planta de tratamiento de residuos sólidos de Cajamarca] | es_PE |
dc.type | info:eu-repo/semantics/article | es_PE |
dc.publisher.country | US | es_PE |
dc.identifier.journal | Proceedings of the LACCEI International Multi-conference for Engineering, Education and Technology | es_PE |
dc.description.peer-review | Revisión por pares | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.07.00 | es_PE |
dc.description.sede | Trujillo San Isidro | es_PE |
dc.identifier.doi | https://doi.org/10.18687/LACCEI2020.1.1.489 |