Mostrar el registro sencillo del ítem
Resistencia a compresión de un mortero cemento-arena (1:3 y 1:4) al reemplazar distintos porcentajes de arena de rio por arena de duna (10 y 20%)
dc.contributor.advisor | Ravines Azañero, Irene Del Rosario | |
dc.contributor.author | Rabanal Altamirano, Oscar Ariyor | |
dc.date.accessioned | 2017-11-14T19:47:09Z | |
dc.date.available | 2017-11-14T19:47:09Z | |
dc.date.issued | 2017-11-06 | |
dc.identifier.citation | Rabanal, O. A. (2017). Resistencia a compresión de un mortero cemento-arena (1:3 y 1:4) al reemplazar distintos porcentajes de arena de rio por arena de duna (10 y 20%) (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/11391 | es_PE |
dc.identifier.other | 624 RABA 2017 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/11391 | |
dc.description.abstract | RESUMEN La presente investigación logró comparar la resistencia a compresión de un mortero cementoarena (1:3 y 1:4) al reemplazar distintos porcentajes de arena de río por arena de duna (10 y 20%). Para esto se ha analizado las propiedades físicas de las arenas de río y duna como son contenido de humedad (W = 5.90% para la arena de río y W = 1.03% para la arena de duna), granulometría (MF = 2.33 para la arena de río y MF = para la arena de duna), peso unitario suelto y compactado (PUSS = 1.70 y PUCS = 1.82 g/cm3 para la arena de río y PUSS = 1.38 g/cm3 y PUCS = 1.57 g/cm3 para la arena de duna), peso específico y porcentaje de absorción que sirvió para diseñar el mortero, adicionalmente se realizó un estudio químico de sales agresivas a la arena de duna para determinar la cantidad de cloruros y sulfatos que contiene; consecuentemente se realizaron las probetas de mortero y se ensayaron en resistencia a compresión a los 3, 7 y 28 días de curado. Con la investigación se determinó: para la dosificación cemento-arena 1:3 con reemplazo del 10% de arena de duna la resistencia disminuye en 6.88% y con reemplazo del 20% de arena de duna la resistencia disminuye en 7.70%; para la dosificación cemento-arena 1:4 con reemplazo del 10% de arena de duna la resistencia disminuye en 3.13% y con reemplazo del 20% de arena de duna la resistencia disminuye en 9.20%; determinándose que la proporción 1:4 posee mejores características. | es_PE |
dc.description.abstract | ABSTRACT The present research seeks to compare the compressive strength of a cement-sand mortar (1: 3 and 1: 4) by replacing different percentages of river sand with sand dune (10 and 20%). For this the physical properties of the river and dune sands have been analyzed as they are moisture content (W = 5.90% for the river sand and W = 1.03% for the sand of dune), granulometry (MF = 2.33 for the sand (PUSS = 1.70 and PUCS = 1.82 g/cm3 for river sand and PUSS = 1.38 g/cm3 and PUCS = 1.57 g/cm3 for the sand dune), specific weight and percentage of absorption that served to design the mortar, in addition a chemical study of aggressive salts to the dune sand was carried out to determine the amount of chloride and sulfates it contains; consequently the test tubes were made and tested in compression resistance at 3, 7 and 28 days of curing. With the research it was determined: for the 1: 3 cement-sand dosage with replacement of 10% of sand dune the resistance decreases in 6.88% and with replacement of 20% of dune sand the resistance decreases in 7.70%; for the 1: 4 cement-sand dosage with 10% sand dune replacement the resistance decreases by 3.13% and with a 20% sand dune replacement the resistance decreases by 9.20%. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.format | application/msword | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights | Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Resistencia a la compresión | es_PE |
dc.subject | Arena | es_PE |
dc.subject | Cemento | es_PE |
dc.title | Resistencia a compresión de un mortero cemento-arena (1:3 y 1:4) al reemplazar distintos porcentajes de arena de rio por arena de duna (10 y 20%) | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Cajamarca | es_PE |
renati.advisor.dni | 40208212 | |
renati.author.dni | 48238170 | |
renati.discipline | 732016 | es_PE |
renati.juror | Aguilar Aliaga, Orlando | |
renati.juror | Sánchez Portal, Fabián Sebastián | |
renati.juror | Alva Sarmiento, Anita Elízabet | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis [1449]