Mostrar el registro sencillo del ítem

dc.contributor.advisorVillarreal Castro, Genner Alvarito
dc.contributor.authorReátegui Fasabi, René
dc.date.accessioned2020-07-23T05:38:40Z
dc.date.available2020-07-23T05:38:40Z
dc.date.issued2020-06-04
dc.identifier.citationReátegui, R. (2020). Comparación de la respuesta estructural de una edificación aporticada con zapatas aisladas considerando y sin considerar interacción suelo estructura en la Urbanización San Isidro II Etapa, Trujillo – 2020 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/23975es_PE
dc.identifier.other624 REAT 2020es_PE
dc.identifier.urihttps://hdl.handle.net/11537/23975
dc.description.abstractLa presente investigación se realizó en la Urbanización San Isidro II Etapa del distrito de Trujillo, enfocada en comparar la respuesta estructural de una edificación aporticada con zapatas aisladas considerando y sin considerar la interacción suelo estructura , puesto que Perú está ubicado en una zona de alta sismicidad siendo indispensable comprender adecuadamente los efectos de Interacción suelo-estructura y dejar de seguir asumiendo que no existe contacto dinámico entre el suelo y la cimentación para garantizar la seguridad de elementos estructurales y la de sus ocupantes. Para el desarrollo de la investigación se ha considerado dos modelos dinámicos, el modelo dinámico de D. D. Barkan – O. A. Savinov y el modelo dinámico de la Norma Rusa SNIP 2.02.05-87. Los dos modelos dinámicos que se desarrollan en la presente investigación corresponden a las diversas investigaciones publicadas por el Ph. D. Genner Villarreal Castro. Como resultado de la comparación del modelo empotrado con respecto a los modelos dinámicos se resuelve que los periodos de vibración y desplazamientos se incrementan, además las fuerzas axiales máximas disminuyen mientras que las fuerzas cortantes y momentos flectores máximos se incrementan. Por lo tanto, se concluye que la interacción suelo estructura permite una mejor respuesta estructural en el análisis de edificaciones y el mayor efecto de flexibilidad en la base de fundación se da en el modelo Norma Rusa. y el menor efecto en el modelo dinámico Barkan.es_PE
dc.description.abstractThe present investigation was carried out in the Urbanization San Isidro II Stage of the District of Trujillo, focused on comparing the structural response of a building provided with isolated footings considering and without considering the interaction soil structure, since Peru is located in a high seismicity area being essential to properly understand the effects of Soil-structure Interaction and stop continuing to assume that there is no dynamic contact between the ground and the foundation to guarantee the safety of structural elements and that of their occupants. For the development of the investigation, two dynamic models have been considered, the dynamic model of D. D. Barkan - O. A. Savinov and the dynamic model of the Russian Standard SNIP 2.02.05-87. The two dynamic models that are developed in the present investigation correspond to the diverse investigations published by Ph. D. Genner Villarreal Castro. As a result of the comparison of the embedded model with respect to the dynamic models, it is resolved that the periods of vibration and displacement increase, in addition the maximum axial forces decrease while the shear forces and maximum bending moments increase. Therefore, it is concluded that the soil-structure interaction allows a better structural response in the analysis of buildings and the greatest effect of flexibility in the foundation base occurs in the Norma Rusa model and the least effect in the dynamic model Barkan.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectEstructurases_PE
dc.subjectElementos estructuraleses_PE
dc.subjectEdificioses_PE
dc.titleComparación de la respuesta estructural de una edificación aporticada con zapatas aisladas considerando y sin considerar interacción suelo estructura en la Urbanización San Isidro II Etapa, Trujillo – 2020es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeTrujillo San Isidroes_PE
renati.advisor.dni17936682
renati.advisor.orcidhttps://orcid.org/0000-0003-1768-646Xes_PE
renati.author.dni76155184
renati.discipline732016es_PE
renati.jurorAvalos Alayo, Ricardo Daniel
renati.jurorDíaz García, Gonzalo Hugo
renati.jurorRamírez Mercado, Roger
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)