Mostrar el registro sencillo del ítem
Sistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados del almacén M. P. S. A. R. C.
dc.contributor.advisor | Chuman Lopez, Margeo Javier | |
dc.contributor.author | Revolledo Chaparro, Ana Paula | |
dc.date.accessioned | 2021-06-25T15:02:11Z | |
dc.date.available | 2021-06-25T15:02:11Z | |
dc.date.issued | 2021-04-30 | |
dc.identifier.citation | Revolledo, A. P. (2021). Sistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados del almacén M. P. S. A. R. C. (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/26950 | es_PE |
dc.identifier.other | 628.168 REVO 2021 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/26950 | |
dc.description.abstract | Las aguas residuales provenientes del lavado de contenedores refrigerados del almacén M.P.S.A.R.C. son vertidas directamente al sistema de alcantarillado sin previo tratamiento lo cual generaría un daño a la infraestructura sanitaria, así como un impacto ambiental negativo ya que no cumplen con los Valores Máximos Admisibles. El objetivo fue evaluar el sistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados mediante un diseño experimental puro. Se consideró como población 1 m3/h y una muestra de 26 litros. En el proceso de Coagulación – Floculación se empleó Coagulante Orgánico, Cloruro Férrico y Policloruro de Aluminio en dosis de 1, 2 y 3 ml/L y dosis constante de 3 ml/L de poliacrilamida aniónica como floculante. En el proceso de adsorción se aplicó 500 g de carbón activado granular evaluando 5 y 10 minutos de contacto. Se determinó que la dosis óptima para cada coagulante fue de 3 ml/L, siendo el Cloruro Férrico el más eficiente, mientras que en el proceso de adsorción se estableció mayor remoción de DQO y turbidez a los 10 minutos de contacto. Tras la culminación del tratamiento del sistema se redujo el 98.11 %, 98.88 %, 99.84 %, 99.50 %, 99.90 % de DBO5, de DQO, SST y AyG respectivamente; cumpliendo con los Valores Máximos Admisibles. | es_PE |
dc.description.abstract | Wastewater from the washing of refrigerated containers of the M.P.S.A.R.C. are discharged directly into the sewerage system without prior treatment, which would generate damage to the sanitary infrastructure, as well as a negative environmental impact since they don’t meet with the Maximum Admissible Values. The objective was to evaluate the coagulation-flocculation and adsorption system at laboratory level for the reduction of the physicochemical parameters from wastewater reefer containers washing through an experimental design. A population of 1 m3 / h and a sample of 26 liters was considered. In the Coagulation - Flocculation process, Organic coagulant, Ferric Chloride and Aluminum Polychloride were used in doses of 1, 2 and 3 ml/L and a constant dose of 3 ml/L of anionic polyacrylamide as flocculant. Adsorption process 500 g of granular activated carbon was applied evaluating 5 and 10 minutes of contact. The optimal dose for each coagulant was 3 ml/L, and Ferric Chloride was the most efficient; while in the adsorption process, the most reduction of COD and turbidity was after 10 minutes of contact. Finally, after system treatment, 98.11%, 98.88%, 99.84%, 99.50%, 99.90% of BOD5, COD, TSS and Oils and Greases respectively were reduced; comply with the Maximum Admissible Values. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.format | application/msword | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Contaminación del agua | es_PE |
dc.subject | Aguas residuales | es_PE |
dc.subject | Calidad del agua | es_PE |
dc.title | Sistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados del almacén M. P. S. A. R. C. | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Título Profesional | es_PE |
thesis.degree.discipline | Ingeniería Ambiental | es_PE |
thesis.degree.name | Ingeniero Ambiental | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.07.00 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Los Olivos | es_PE |
renati.advisor.dni | 45997406 | |
renati.advisor.orcid | https://orcid.org/0000-0002-4038-7591 | es_PE |
renati.author.dni | 74072365 | |
renati.discipline | 521066 | es_PE |
renati.juror | Landa Acuña, Daniela Milagros | |
renati.juror | Temoche López, Alfredo | |
renati.juror | Murga González, Iselli | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | https://purl.org/pe-repo/renati/type#tesis | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis [600]