Mostrar el registro sencillo del ítem

dc.contributor.advisorChuman Lopez, Margeo Javier
dc.contributor.authorRevolledo Chaparro, Ana Paula
dc.date.accessioned2021-06-25T15:02:11Z
dc.date.available2021-06-25T15:02:11Z
dc.date.issued2021-04-30
dc.identifier.citationRevolledo, A. P. (2021). Sistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados del almacén M. P. S. A. R. C. (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/26950es_PE
dc.identifier.other628.168 REVO 2021es_PE
dc.identifier.urihttps://hdl.handle.net/11537/26950
dc.description.abstractLas aguas residuales provenientes del lavado de contenedores refrigerados del almacén M.P.S.A.R.C. son vertidas directamente al sistema de alcantarillado sin previo tratamiento lo cual generaría un daño a la infraestructura sanitaria, así como un impacto ambiental negativo ya que no cumplen con los Valores Máximos Admisibles. El objetivo fue evaluar el sistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados mediante un diseño experimental puro. Se consideró como población 1 m3/h y una muestra de 26 litros. En el proceso de Coagulación – Floculación se empleó Coagulante Orgánico, Cloruro Férrico y Policloruro de Aluminio en dosis de 1, 2 y 3 ml/L y dosis constante de 3 ml/L de poliacrilamida aniónica como floculante. En el proceso de adsorción se aplicó 500 g de carbón activado granular evaluando 5 y 10 minutos de contacto. Se determinó que la dosis óptima para cada coagulante fue de 3 ml/L, siendo el Cloruro Férrico el más eficiente, mientras que en el proceso de adsorción se estableció mayor remoción de DQO y turbidez a los 10 minutos de contacto. Tras la culminación del tratamiento del sistema se redujo el 98.11 %, 98.88 %, 99.84 %, 99.50 %, 99.90 % de DBO5, de DQO, SST y AyG respectivamente; cumpliendo con los Valores Máximos Admisibles.es_PE
dc.description.abstractWastewater from the washing of refrigerated containers of the M.P.S.A.R.C. are discharged directly into the sewerage system without prior treatment, which would generate damage to the sanitary infrastructure, as well as a negative environmental impact since they don’t meet with the Maximum Admissible Values. The objective was to evaluate the coagulation-flocculation and adsorption system at laboratory level for the reduction of the physicochemical parameters from wastewater reefer containers washing through an experimental design. A population of 1 m3 / h and a sample of 26 liters was considered. In the Coagulation - Flocculation process, Organic coagulant, Ferric Chloride and Aluminum Polychloride were used in doses of 1, 2 and 3 ml/L and a constant dose of 3 ml/L of anionic polyacrylamide as flocculant. Adsorption process 500 g of granular activated carbon was applied evaluating 5 and 10 minutes of contact. The optimal dose for each coagulant was 3 ml/L, and Ferric Chloride was the most efficient; while in the adsorption process, the most reduction of COD and turbidity was after 10 minutes of contact. Finally, after system treatment, 98.11%, 98.88%, 99.84%, 99.50%, 99.90% of BOD5, COD, TSS and Oils and Greases respectively were reduced; comply with the Maximum Admissible Values.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectContaminación del aguaes_PE
dc.subjectAguas residualeses_PE
dc.subjectCalidad del aguaes_PE
dc.titleSistema de coagulación-floculación y adsorción a nivel de laboratorio para la reducción de los parámetros fisicoquímicos en las aguas residuales del lavado de contenedores refrigerados del almacén M. P. S. A. R. C.es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Ambientales_PE
thesis.degree.nameIngeniero Ambientales_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.07.00es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeLos Olivoses_PE
renati.advisor.dni45997406
renati.advisor.orcidhttps://orcid.org/0000-0002-4038-7591es_PE
renati.author.dni74072365
renati.discipline521066es_PE
renati.jurorLanda Acuña, Daniela Milagros
renati.jurorTemoche López, Alfredo
renati.jurorMurga González, Iselli
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess