dc.identifier.citationGutarra, R. L. (2021). Ahorro energético mediante la optimización de funcionamiento de la bomba CPH en los HRSG de una central térmica de ciclo combinado de 870 megavatios ubicada en el distrito de Chilca - Lima [Trabajo de suficiencia profesional, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/28184es_PE
dc.identifier.other338.51GUTA 2021es_PE
dc.identifier.urihttps://hdl.handle.net/11537/28184
dc.description.abstractLa siguiente implementación de ahorro energético tiene como propósito optimizar el funcionamiento de la bomba CPH (Condensate Preheater) de acuerdo a la temperatura optima de ingreso al precalentador del HRSG (Heat Recovery Steam Generators) de la Central Térmica de Ciclo Combinado Kallpa de 870 MW ubicada en el distrito de Chilca, Lima – Perú; esto a fin de reducir el Consumo de Energía Auxiliares de la Central. Para ello se realizó el diagnóstico de operación actual de la bomba CPH, así como el cálculo del consumo de energía eléctrica, y finalmente el análisis termodinámico balance de masa y energía en el precalentador del HRSG. La implementación tomó 46 días laborables, cuyas etapas comprenden: Gestión De Control de Cambios; Implementación, Establecer Recursos a Utilizar; Establecer Funciones, Procedimientos y Documentación; Medir y Mantener la Gestión. Se obtuvo un ahorro mensual energético de 42,46 MW-h y económico de $ 2 123,17 por las 3 bombas CPH del HRSG1-2-3 después de aplicar el método termodinámico balance de masa y energía en el precalentador de condensado del HRSG. De acuerdo a los resultados obtenidos producto de la implementación se cumple con el objetivo de reducir el consumo de auxiliares de energía de la Central Térmica de Ciclo Combinado Kallpa de 248,5 MW-h a 206,04 MW-h, el cual representa un ahorro mensual en promedio de 42,46 MW-h. Esto en condiciones normales de operación del ciclo combinado para una configuración de 3x1.es_PE
dc.description.abstractThe following energy saving implementation aims to optimize the operation of the CPH (Condensate Preheater) pump according to the optimal inlet temperature to the HRSG (Heat Recovery Steam Generators) preheater of the 870 MW Kallpa Combined Cycle Power Plant located in the district of Chilca, Lima - Peru; this in order to reduce the Auxiliary Power Consumption of the Plant. For this, the current operation diagnosis of the C PH pump was carried out, as well as the calculation of the electrical energy consumption, and finally the thermodynamic analysis of the mass and energy balance in the HRSG preheater. The implementation took 25 working days, whose stages include: Change Control Management; Implementation, Establish Resources to Use; Establish Functions, Procedures and Documentation; Measure and Maintain Management. A monthly energy saving of 42.46 MW-h and an economic saving of $ 2 123.17 was obtained for the 3 CPH pumps of the HRSG1-2-3 after applying the thermodynamic method of mass and energy balance in the HRSG condensate preheater . According to the results obtained as a result of the implementation, the objective of reducing the consumption of auxiliary energy at the Kallpa Combined Cycle Thermal Power Plant from 248.5 MW-h to 206.04 MW-h is met, which represents a monthly savings on average of 42.46 MW-h. This under normal combined cycle operating conditions for a 3x1 configuration.es_PE
dc.description.uriTrabajo de suficiencia profesionales_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectBombas (mecánica)es_PE
dc.subjectTermodinámicaes_PE
dc.subjectEstaciones de bombeoes_PE
dc.titleAhorro energético mediante la optimización de funcionamiento de la bomba CPH en los HRSG de una central térmica de ciclo combinado de 870 megavatios ubicada en el distrito de Chilca - Limaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Industriales_PE
thesis.degree.nameIngeniero Industriales_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.11.04es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeLos Olivoses_PE
renati.advisor.dni42900946
renati.advisor.orcidhttps://orcid.org/0000-0003-4624-4564es_PE
renati.author.dni44821167
renati.discipline722026es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess