Mostrar el registro sencillo del ítem

dc.contributor.advisorDíaz García, Gonzalo Hugo
dc.contributor.authorDiaz Rodriguez, Breitner Guillermo
dc.contributor.authorNarro Mendez, Anthony Leoneld
dc.date.accessioned2022-01-27T21:34:52Z
dc.date.available2022-01-27T21:34:52Z
dc.date.issued2021-11-26
dc.identifier.citationDiaz, B. G., & Narro, A. L. (2021). BIM 5D para performance estructural con sistema de aislamiento de la base en un edificio de 8 pisos, Trujillo 2021 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/29185es_PE
dc.identifier.other624.1762 DIAZ 2021es_PE
dc.identifier.urihttps://hdl.handle.net/11537/29185
dc.description.abstractLa presente investigación realizada es sobre la disminución de la demanda sísmica para las estructuras, cuando se emplean aisladores de base elastoméricos, estableciendo una comparación entre estructuras convencionales con base fija y estructura aislada en su base. Para este caso de estudio perteneciente a la Industria de la Construcción se tiene diferentes tipos de aisladores de base entre ellos las gomas de alto amortiguamiento, las gomas de bajo amortiguamiento con núcleo de plomo y el sistema de péndulo de ficción, lo cual se utilizó el de Núcleo de Plomo dado que se define las propiedades del aislador empleando el modelo bilineal, el modelado y los análisis correspondientes que se desarrollan empleando el ETABS Los resultados del presente documento miden la reducción de la demanda sísmica (desplazamientos y aceleraciones) y evidencian su Performance Estructural adecuado, lo cual es de importancia en emplear técnicas de control estructural para lograr un nivel de desempeño superior garantizando la seguridad a la vida y la integridad de la estructura y sus contenidos para sismos con intensidades altas. Se puede también mencionar que en edificaciones importantes en diferentes partes del país a largo plazo se podrá obtener un beneficio y prevención no solo estructural; sino también una estimación de costos para una rentabilidad y/o evaluación económica viable, así como utilizando y aplicando en forma innovadora con BIM 5Des_PE
dc.description.abstractThe present investigation carried out is on the reduction of the seismic demand for the structures, when elastomeric base insulators are used, establishing a comparison between conventional structures with a fixed base and an isolated structure at its base. For this case study belonging to the Construction Industry, there are different types of base insulators, including high damping rubbers, low damping rubbers with lead core and the fictional pendulum system, which was used of Lead Core since the properties of the insulator are defined using the bilinear model, the modeling and the corresponding analyzes that are developed using the ETABS The results of this document measure the reduction of the seismic demand (displacements and accelerations) and show its Performance Adequate structural, which is important in employing structural control techniques to achieve a higher level of performance, guaranteeing life safety and the integrity of the structure and its contents for earthquakes with high intensity. It can also be mentioned that in important buildings in different parts of the country in the long term it will be possible to obtain a benefit and prevention not only structural; but also a cost estimate for a profitability and / or viable economic evaluation as well as using and applying in an innovative way with BIM 5Des_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectConstrucciónes_PE
dc.subjectDiseño sísmico de edificioses_PE
dc.subjectDiseño estructurales_PE
dc.subjectDiseño arquitectónicoes_PE
dc.titleBIM 5D para performance estructural con sistema de aislamiento de la base en un edificio de 8 pisos, Trujillo 2021es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeTrujillo San Isidroes_PE
renati.advisor.dni40539624
renati.advisor.orcidhttps://orcid.org/0000-0002-3441-8005es_PE
renati.author.dni43153608
renati.author.dni48312618
renati.discipline732016es_PE
renati.jurorSagastegui Vasquez, German
renati.jurorVillar Quiroz, Josualdo Carlos
renati.jurorRodriguez Beltran, Eduar Jose
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess