Dosimetric evaluation of radiopharmaceuticals in kidneys and uterine wall of a woman with early pregnancy using Stabin/Segars representations
Date
2021-08-04Author(s)
Vasquez Arteaga, Marcial
Vega Carrillo, Hector Rene
Saavedra, L. Carlos
Rodriguez, B. Carlos
Rodriguez, N. Huber
Chanduvi, C. Roger
Vasquez, S. Marcela
Metadata
Show full item recordAbstract
MIRD method with the Stabin/Segars anthropomorphic representations were used to calculate the absorbed doses in kidneys and uterine wall of an early-stage pregnant woman when 99mTc (DTPA), 99mTc (DMSA) and 99mTc (MAG3) are used for renal studies. Stabin and Segars anatomical representations are phantoms that are used in Monte Carlo calculations to determine the SAF, that with the pharmaceutical residence time are used to calculate the absorbed dose, from source organs, on target organs. Concerns about the impact on the absorbed dose due to the use of the three 99mTc-based compounds as well as the use of different phantoms were here treated for the case of a female at early pregnant state. The lowest absorbed dose in the kidneys was obtained with 99mTc (MAG3), and the relative difference of using Stabin and Segars anthropomorphic representations was 2.5%. For bladder and rest of organs the relative difference 14.63%. The lowest absorbed dose by uterine wall was obtained with 99mTc(DMSA), however the relative difference of using Stabin and Segars anthropomorphic representations was 12%.
Mostrar más
Bibliographic citation
Vasquez, M., Vega, H., Saavedra, L., Rodriguez, B., Rodriguez, N., & Chanduvi, C. (2021). Dosimetric evaluation of radiopharmaceuticals in kidneys and uterine wall of a woman with early pregnancy using Stabin/Segars representations. Applied Radiation and Isotopes, 176. https://doi.org/10.1016/j.apradiso.2021.109888
Note
El texto completo de este trabajo no está disponible en el Repositorio Académico UPN por restricciones de la casa editorial donde ha sido publicado.
Collections
The following license files are associated with this item:
Related items
Showing items related by title, author, creator and subject.
-
Dosymmetric estimates of 99mTc (MAA) and 133Xe in newborn lungs using Cristy-Eckerman / Segars représentations [Estimaciones dosimétricas del 99mTc (MAA) y 133Xe en los pulmones de recién nacidos utilizando las representaciones de Cristy-Eckerman/Segars]
Vasquez-Arteaga, Marcial; Vega-Carrillo, Hector; Montalvo-Soberon, Gustavo; Rivera-Vasquez, Juan; Jaramillo-Arica, Pedro; Vasquez-Silva, Marcela; Cabrera-Salvatierra, Carlos; Rojas-Alegria, Roberto (Universidad Nacional de Colombia, 2022-01-05)Acceso abiertoUsing the Cristy-Eckerman (C-E) / Segars anatomical representations and the MIRD formalism, the Absorbed doses in lungs of newborn patients scanned with radiopharmaceuticals 133Xe (ventilation) and 99mTc (MAA) (perfusion) ... -
Dosimetric evaluation of 123I (Iodide) and 99mTc (Pertechnetate) in the thyroid of neonates using Cristy-Eckerman and Segars anatomical representations
Vasquez Arteaga, Marcial; Vega Carrillo, Hector Rene; Acuña Peralta, Leopoldo; Rodriguez Nomura, Huber; Vasquez Silva, Marcela; Flores Urquiaga, Hipólito (Elsevier Ltd., 2023)Acceso cerradoUsing the MIRD formalism, and the Cristy-Eckeman and Segars anthropomorphic representations, the absorbed dose in the thyroid of newborns, was calculated when 123I (iodide) and 99mTc (pertechnetate) are used during the ... -
La influencia de la adición de fibra de coco en las propiedades físicas y mecánicas del mortero, ciudad de Lima, año 2020
Gutierrez Espinoza, Luis Angel (Universidad Privada del Norte, 2021-05-20)Acceso abiertoEn el presente trabajo de investigación se da a conocer la influencia en las propiedades físicas y mecánicas del mortero al aplicarle un porcentaje fijo de fibra de estopa de coco de 2 longitudes distintas, basándose en ...