Mostrar el registro sencillo del ítem

dc.contributor.advisorCubas Becerra, Alejandro
dc.contributor.authorAlcalde Paredes, Susan Grettel
dc.date.accessioned2016-11-03T02:17:54Z
dc.date.available2016-11-03T02:17:54Z
dc.date.issued2016-05-19
dc.identifier.citationAlcalde, S. G. (2015). Evaluación del agregado proveniente de la cantera “Rio Cajamarquino” para la elaboración de concreto permeable para pavimento rígido, Cajamarca 2015 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/7333es_PE
dc.identifier.other624 ALCA 2015es_PE
dc.identifier.urihttps://hdl.handle.net/11537/7333
dc.description.abstractLa presente investigación se enfoca en analizar un agregado proveniente de la cantera “Río Cajamarquino” con el fin de determinar si sus propiedades físico – mecánicas permiten fabricar un concreto permeable que cumpla con la resistencia mínima para su uso en pavimentos en la ciudad de Cajamarca. Se analizó al agregado por medio de ensayos de laboratorio propuestos según las normas peruanas en vigencia (NTP) y se determinaron sus características para la fabricación de concreto permeable con un porcentaje de vacíos adecuado para la cuenca de Cajamarca. Se realizó el diseño de mezcla según lo establecido por el ACI 211.3R-02 y se comparó el resultado de resistencia a compresión con la resistencia mínima requerida para su utilización en pavimentos rígidos (f’c=210km/cm2). Los resultados de los ensayos realizados para el agregado y concreto, muestran mediante indicadores, sus propiedades y características. Teniendo como resultado de los ensayos a los agregados; contenido de humedad 3.99%, granulometría con el huso 67, porcentaje de abrasión 24.65%, Peso unitario de agregado porcentaje de absorción 2.02%, peso unitario 1639.36 kg/m3; y los resultados del ensayo a compresión de las probetas de concreto a 28 días con f’c=68.41kg/cm2. Finalmente, de los ensayos, se determinó que el agregado por sí solo, no cumple lo requerido para fabricar un concreto drenante ya que su resistencia 28 días no satisface la necesaria.es_PE
dc.description.abstractPresent research focuses on analyzing aggregate from the quarry "Río Cajamarquino” in order to determine if their physical - mechanical properties allow fabricate permeable concrete that meets the minimum resistance for use in pavements in the city of Cajamarca. We analyzed the aggregate through laboratory tests proposed by Peruvian standards in force (NTP) and its characteristics were determined for making pervious concrete with a percentage of empty suitable for the basin of Cajamarca. Mix design was performed as established by ACI 211.3R -02, appendix 6 and the result of compressive strength with the minimum strength required for use in rigid pavements (f’c = 210km / cm2) was compared The results of tests conducted for aggregate and concrete, shown by indicators, their properties and characteristics. Taking as a result of the tests aggregates; 3.99% moisture content, particle size with the spindle 67, abrasion percentage of 24.65 %, Unit weight aggregate absorption rate 2.02 %, unit weight 1639.36 kg/m3; and the test results of compressive concrete specimens 28 days with f’c=68.41kg/cm2. Finally, of the tests, it was determined to that, the concrete without addition not achieved the resistance required for a pervious concrete to 28 days.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de Américaes_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectCanterases_PE
dc.subjectConcretoes_PE
dc.subjectPermeabilidades_PE
dc.subjectPavimentoses_PE
dc.titleEvaluación del agregado proveniente de la cantera “Rio Cajamarquino” para la elaboración de concreto permeable para pavimento rígido, Cajamarca 2015es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeCajamarcaes_PE
renati.advisor.dni26623287
renati.advisor.orcidhttps://orcid.org/0000-0001-8162-965Xes_PE
renati.author.dni70207817
renati.discipline732016es_PE
renati.jurorAguilar Aliaga, Orlando
renati.jurorChávez Toledo, Teresa
renati.jurorMejía Díaz, Iván
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess