Mostrar el registro sencillo del ítem
Estudio comparativo de los tratamientos de electrocoagulación y coagulación/ floculación para la remoción de contaminantes de aguas residuales del camal Conchucos, Lima, 2021
dc.contributor.advisor | Chuman López, Margeo Javier | |
dc.contributor.author | Meliton Romero, Jeny | |
dc.contributor.author | Miyashiro Aguirre, Ruth Megumi | |
dc.date.accessioned | 2022-09-08T00:20:51Z | |
dc.date.available | 2022-09-08T00:20:51Z | |
dc.date.issued | 2022-05-31 | |
dc.identifier.citation | Meliton, J., & Miyashiro, R. M. (2022). Estudio comparativo de los tratamientos de electrocoagulación y coagulación/ floculación para la remoción de contaminantes de aguas residuales del camal Conchucos, Lima, 2021 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/31248 | es_PE |
dc.identifier.other | 628.32 MELI/E 2022 | es_PE |
dc.identifier.uri | https://hdl.handle.net/11537/31248 | |
dc.description.abstract | En este trabajo se comparó los tratamientos de coagulación-floculación y electrocoagulación en la remoción de contaminantes de aguas residuales del camal Conchucos, Lima. Para el tratamiento de coagulación-floculación se trabajó con 4 variables independientes con sus respectivos rangos de experimentación, dosis de coagulante (600 1000 mg/L), dosis de floculante (4-8 mg/L), velocidad de agitación rápida (250-350 rpm), velocidad de agitación lenta (80-100 rpm), para la electrocoagulación los parámetros de velocidad de agitación (250-350 rpm) y tiempo de agitación (15-30 rpm). Se usó el método de diseño central compuesto (DCC) optimizando mediante superficie de respuesta (RSM) como método experimental para la reducción de contaminantes en función de la demanda química de oxígeno (%DQO), se usó un equipo de prueba de jarras para la coagulación floculación y un agitador de un litro con electrodos de placa de aluminio a 30 V. Los resultados muestran que la coagulación/floculación y electrocoagulación presentaron modelos estadísticos con valores F de 5.33, 20.30, significancias p < 0,05, con ajustes de R2 de 0,6179, y 0,7571 para un arreglo óptimo con predicciones de reducción de %DQO, respectivamente. El tratamiento de electrocoagulación presento una reducción de 75.43% similar al modelo predecido, de los 2 tratamientos comparados la electroremediación está por debajo de los valores máximos admisibles (VMA) en DQO, DBO y Aceites y Grasas cumpliendo los parámetros necesarios para el vertimiento a la red de alcantarillado. | es_PE |
dc.description.abstract | In this work, the coagulation-flocculation and electrocoagulation treatments were compared in the removal of pollutants from wastewater from the Conchucos slaughterhouse, Lima. For the coagulation-flocculation treatment, we worked with 4 independent variables with their respective experimental ranges, coagulant dose (600-1000 mg / L), flocculant dose (4-8 mg / L), fast stirring speed (250-350 rpm) , slow stirring speed (80-100 rpm), for electrocoagulation the parameters of stirring speed (250-350 rpm) and stirring time (15-30 rpm). The central compound design method (DCC) optimizing by response surface (RSM) was used as an experimental method for the reduction of pollutants as a function of chemical oxygen demand (% COD), a jar test equipment was used for the coagulation-flocculation and a one-liter shaker with aluminum plate electrodes at 30 V. The results show that coagulation / flocculation and electrocoagulation presented statistical models with F values of 5.33, 20.30, significance p<0.05, with adjustments of R2 of 0.6179, and 0.7571 for an optimal arrangement with % COD reduction predictions, respectively. The electrocoagulation treatment presented a reduction of 75.43% similar to the predicted model, of the 2 treatments compared, the electroremediation is below the maximum admissible values (VMA) in COD, BOD and Oils and Fats, complying with the necessary parameters for the discharge to the sewerage system. | es_PE |
dc.description.uri | Tesis | es_PE |
dc.format | application/pdf | es_PE |
dc.format | application/msword | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Privada del Norte | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
dc.source | Universidad Privada del Norte | es_PE |
dc.source | Repositorio Institucional - UPN | es_PE |
dc.subject | Aguas residuales | es_PE |
dc.subject | Contaminación | es_PE |
dc.subject | Ganadería | es_PE |
dc.subject | Matadero | es_PE |
dc.subject | Coagulación | es_PE |
dc.subject | Floculación | es_PE |
dc.title | Estudio comparativo de los tratamientos de electrocoagulación y coagulación/ floculación para la remoción de contaminantes de aguas residuales del camal Conchucos, Lima, 2021 | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.grantor | Universidad Privada del Norte. Facultad de Ingeniería | es_PE |
thesis.degree.level | Ingeniero | es_PE |
thesis.degree.discipline | Ingeniería Ambiental | es_PE |
thesis.degree.name | Ingeniero Ambiental | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.07.00 | es_PE |
thesis.degree.program | Pregrado | es_PE |
dc.description.sede | Los Olivos | es_PE |
renati.advisor.dni | 45997406 | |
renati.advisor.orcid | https://orcid.org/0000-0002-4038-7591 | es_PE |
renati.author.dni | 73987894 | |
renati.author.dni | 72185906 | |
renati.discipline | 521066 | es_PE |
renati.juror | Torres Joaquin, Haniel Josue | |
renati.juror | Cateriano Calderón, Margarita del Carmen | |
renati.juror | Alva Mendoza, Denisse Milagros | |
renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | es_PE |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis [535]