Mostrar el registro sencillo del ítem

dc.contributor.advisorGallo Portocarrero, Saulo
dc.contributor.authorZevallos Torres, Oscar
dc.date.accessioned2021-02-25T23:35:11Z
dc.date.available2021-02-25T23:35:11Z
dc.date.issued2020-12-03
dc.identifier.citationZevallos, O. (2020). Influencia de porcentajes de poliestireno expandido al 20%, 35%, 50% y 65% en el diseño de concreto liviano para la elaboración de unidades de albañilería evaluados a compresión (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/25050es_PE
dc.identifier.other620.1124 ZEVA 2020es_PE
dc.identifier.urihttps://hdl.handle.net/11537/25050
dc.description.abstractLa presente investigación muestra los procesos y procedimientos necesarios para la obtención de un concreto liviano (a base de adición de porcentajes de poliestireno), para la obtención de unidades de albañilería que cumplan con los requerimientos mínimos de las normas para muros no portantes. Los resultados demuestran la posibilidad de uso de dicho concreto con beneficio en la reducción del peso en edificaciones, generando la posibilidad de diseños más eficientes a nivel estructural. Se ha considerado la evaluación de un concreto con agregado liviano (poliestireno expandido) en porcentajes de 20%, 35%, 50% y 65%, evaluado en su peso, nivel de absorción y resistencia a la compresión frente al concreto convencional. Se ha empleado diferentes porcentajes (15% de diferencia) en la elaboración de concreto liviano con la finalizad de analizar el porcentaje máximo posible a emplear. Los resultados mostraron que de todos los porcentajes de agregado liviano empleados, los porcentajes de 20% y 35% cumplen con los requisitos mínimos de resistencia, mientras que los de 50% y 65% comprometen sus resistencias severamente. No se ha determinado la forma, ni dimensiones específicas de las unidades de albañilería a emplear para este concreto, sin embargo, para el análisis de la eficiencia en carga muerta en muros no portantes, se comparó con bloques de concreto de 2 huecos, cuya dimensión es de 15cm (ancho) x 20 cm (alto) x 40 cm (profundidad) y su peso promedio es de 13 kg.es_PE
dc.description.abstractThis research shows the processes and procedures necessary to obtain a lightweight concrete (based on the addition of polystyrene percentages), to obtain masonry units that meet the minimum requirements of the standards for non-bearing walls. The results demonstrate the possibility of using said concrete with benefit in reducing the weight in buildings, generating the possibility of more efficient designs at a structural level. The evaluation of a concrete with light aggregate (expanded polystyrene) has been considered in percentages of 20%, 35%, 50% and 65%, evaluated in its weight, level of absorption and resistance to compression compared to conventional concrete. Different percentages (15% difference) have been used in the preparation of lightweight concrete in order to analyze the maximum possible percentage to use. The results showed that of all the light aggregate percentages used, the percentages of 20% and 35% meet the minimum strength requirements, while those of 50% and 65% severely compromise their strengths. The shape or specific dimensions of the masonry units to be used for this concrete have not been determined, however for the analysis of dead load efficiency in non-bearing walls, it was compared with 2-hole concrete blocks, whose dimension is 15cm (width) x 20 cm (height) x 40 cm (depth) and its average weight is 13 kg.es_PE
dc.description.uriTesises_PE
dc.formatapplication/pdfes_PE
dc.formatapplication/mswordes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Privada del Nortees_PE
dc.rightsinfo:eu-repo/semantics/embargoedAccesses_PE
dc.sourceUniversidad Privada del Nortees_PE
dc.sourceRepositorio Institucional - UPNes_PE
dc.subjectResistencia a la compresiónes_PE
dc.subjectAlbañilería de concretoes_PE
dc.subjectMateriales de construcciónes_PE
dc.titleInfluencia de porcentajes de poliestireno expandido al 20%, 35%, 50% y 65% en el diseño de concreto liviano para la elaboración de unidades de albañilería evaluados a compresiónes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.grantorUniversidad Privada del Norte. Facultad de Ingenieríaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.disciplineIngeniería Civiles_PE
thesis.degree.nameIngeniero Civiles_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_PE
thesis.degree.programPregradoes_PE
dc.description.sedeBreñaes_PE
renati.advisor.dni45811024
renati.advisor.orcidhttps://orcid.org/0000-0001-6728-7251es_PE
renati.author.dni10722562
renati.discipline732016es_PE
renati.jurorCerna Vásquez, Marco Antonio
renati.jurorMendoza Montalvo, Jimmy
renati.jurorSalas Paulet, Manuel Jesús
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem